Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
769
matching recommendationsNAICS | 325412 | Pharmaceutical Preparation Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UU0064 # 03 Y:2004 | 03 | 2004 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $2,624 | $2,400 | Not Implemented |
UU0064 # 04 Y:2004 | 04 | 2004 | RECOVER WASTE HEAT FROM EQUIPMENT | $1,252 | $1,754 | Implemented |
UU0064 # 05 Y:2004 | 05 | 2004 | TURN OFF EQUIPMENT WHEN NOT IN USE | $1,785 | $0 | Implemented |
UU0064 # 06 Y:2004 | 06 | 2004 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $5,480 | $0 | Implemented |
WI0472 # 01 Y:2004 | 01 | 2004 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $6,956 | $16,640 | n/a |
WI0472 # 02 Y:2004 | 02 | 2004 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $5,258 | $9,780 | n/a |
WI0472 # 03 Y:2004 | 03 | 2004 | INSTALL OCCUPANCY SENSORS | $1,700 | $5,500 | n/a |
WI0472 # 04 Y:2004 | 04 | 2004 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $596 | $640 | n/a |
WI0472 # 05 Y:2004 | 05 | 2004 | USE CLOSED CYCLE PROCESS TO MINIMIZE WASTE WATER PRODUCTION | $1,375 | $1,145 | n/a |
WI0472 # 06 Y:2004 | 06 | 2004 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $1,106 | $5,500 | n/a |
WI0472 # 07 Y:2004 | 07 | 2004 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $566 | $500 | n/a |
WI0472 # 08 Y:2004 | 08 | 2004 | RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS | $1,032 | $700 | n/a |
NC0283 # 01 Y:2004 | 01 | 2004 | ADD EQUIPMENT/ OPERATORS TO REDUCE PRODUCTION BOTTLENECK | $22,500 | $18,300 | Not Implemented |
NC0283 # 02 Y:2004 | 02 | 2004 | RECOVER AND REUSE COOLING WATER | $7,112 | $6,000 | Implemented |
NC0283 # 03 Y:2004 | 03 | 2004 | USE HEAT FROM BOILER BLOWDOWN TO PREHEAT BOILER FEED WATER | $1,469 | $1,200 | Implemented |
NC0283 # 04 Y:2004 | 04 | 2004 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,379 | $6,899 | Not Implemented |
NC0283 # 05 Y:2004 | 05 | 2004 | INSTALL OCCUPANCY SENSORS | $1,077 | $356 | Implemented |
MS0224 # 01 Y:2003 | 01 | 2003 | USE COMBINED CYCLE GAS TURBINE GENERATOR SETS WITH WASTE HEAT BOILERS CONNECTED TO TURBINE EXHAUST | $936,645 | $8,400,000 | n/a |
MS0224 # 02 Y:2003 | 02 | 2003 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $351,990 | $119,086 | n/a |
MS0224 # 03 Y:2003 | 03 | 2003 | INSTALL STEAM TRAP | $76,374 | $12,262 | Not Implemented |
MS0224 # 04 Y:2003 | 04 | 2003 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $68,515 | $153,750 | Not Implemented |
MS0224 # 05 Y:2003 | 05 | 2003 | MAINTAIN STEAM JETS USED FOR VACUUM SYSTEM | $37,053 | $70,000 | n/a |
MS0224 # 06 Y:2003 | 06 | 2003 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $31,243 | $26,302 | Implemented |
MS0224 # 07 Y:2003 | 07 | 2003 | USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING | $26,018 | $50,000 | n/a |
MS0224 # 08 Y:2003 | 08 | 2003 | RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS | $12,652 | $0 | Not Implemented |