Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
166
matching recommendationsNAICS | 325510 | Paint and Coating Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
OK0978 # 03 Y:2017 | 03 | 2017 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $2,233 | $2,000 | Implemented |
MI0312 # 10 Y:2017 | 10 | 2017 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,241 | $1,660 | Implemented |
MI0312 # 08 Y:2017 | 08 | 2017 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $5,938 | $960 | Implemented |
MI0312 # 07 Y:2017 | 07 | 2017 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $6,544 | $19,300 | Implemented |
MI0312 # 05 Y:2017 | 05 | 2017 | USE PHOTOCELL CONTROLS | $9,752 | $8,000 | Implemented |
MI0312 # 01 Y:2017 | 01 | 2017 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $12,284 | $33,139 | Implemented |
MI0312 # 03 Y:2017 | 03 | 2017 | TURN OFF EQUIPMENT WHEN NOT IN USE | $9,806 | $3,600 | Implemented |
MI0312 # 04 Y:2017 | 04 | 2017 | INSTALL OCCUPANCY SENSORS | $9,922 | $1,995 | Implemented |
OK0908 # 03 Y:2015 | 03 | 2015 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $621 | $432 | Implemented |
OK0908 # 01 Y:2015 | 01 | 2015 | OPTIMIZE PLANT POWER FACTOR | $6,429 | $11,430 | Implemented |
UD0898 # 07 Y:2014 | 07 | 2014 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $621 | $20 | Implemented |
UD0898 # 01 Y:2014 | 01 | 2014 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $156 | $50 | Implemented |
UD0898 # 04 Y:2014 | 04 | 2014 | COVER OPEN TANKS | $57 | $200 | Implemented |
UD0898 # 08 Y:2014 | 08 | 2014 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $309 | $0 | Implemented |
SD0477 # 05 Y:2013 | 05 | 2013 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $2,263 | $200 | Implemented |
SU0353 # 01 Y:2013 | 01 | 2013 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $839 | $0 | Implemented |
SU0353 # 03 Y:2013 | 03 | 2013 | INSTALL OCCUPANCY SENSORS | $896 | $273 | Implemented |
SU0353 # 04 Y:2013 | 04 | 2013 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $424 | $345 | Implemented |
SU0353 # 05 Y:2013 | 05 | 2013 | CONVERT COMBUSTION EQUIPMENT TO BURN NATURAL GAS | $2,685 | $3,075 | Implemented |
SU0353 # 08 Y:2013 | 08 | 2013 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $18 | $29 | Implemented |
SU0353 # 06 Y:2013 | 06 | 2013 | REPLACE BOILER | $34,391 | $40,935 | Implemented |
SU0353 # 07 Y:2013 | 07 | 2013 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $627 | $737 | Implemented |
UD0886 # 07 Y:2013 | 07 | 2013 | INSTALL MOTOR VOLTAGE CONTROLLER ON LIGHTLY LOADED MOTORS | $36,728 | $14,900 | Implemented |
UD0886 # 14 Y:2013 | 14 | 2013 | INSTALL SMALLER BOILER (INCREASE HIGH FIRE DUTY CYCLE) | $2,995 | $0 | Implemented |
UD0886 # 12 Y:2013 | 12 | 2013 | INSULATE GLAZING, WALLS, CEILINGS, AND ROOFS | $3,648 | $6,720 | Implemented |