Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
357
matching recommendationsNAICS | 32561 | Soap and Cleaning Compound Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
WI0464 # 08 Y:2004 | 08 | 2004 | INSTALL OCCUPANCY SENSORS | $149 | $149 | Not Implemented |
WI0464 # 01 Y:2004 | 01 | 2004 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $15,751 | $48,510 | n/a |
WI0464 # 02 Y:2004 | 02 | 2004 | REPLACE CITY WATER WITH RECYCLED WATER VIA COOLING TOWER | $3,969 | $6,500 | Not Implemented |
WI0464 # 03 Y:2004 | 03 | 2004 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $3,856 | $0 | Implemented |
WI0464 # 04 Y:2004 | 04 | 2004 | RECOVER WASTE HEAT FROM EQUIPMENT | $1,860 | $1,000 | Implemented |
WI0464 # 05 Y:2004 | 05 | 2004 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,256 | $428 | Not Implemented |
WI0464 # 06 Y:2004 | 06 | 2004 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $468 | $0 | Not Implemented |
WI0464 # 07 Y:2004 | 07 | 2004 | INSTALL AUTOMATIC STACK DAMPER | $409 | $1,800 | Not Implemented |
NC0277 # 01 Y:2004 | 01 | 2004 | INCREASE AMOUNT OF WASTE RECOVERED FOR RESALE | $40,000 | $1,000 | Not Implemented |
NC0277 # 02 Y:2004 | 02 | 2004 | DEVELOP A REPAIR/REPLACE POLICY | $2,250 | $710 | Implemented |
NC0277 # 03 Y:2004 | 03 | 2004 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $3,330 | $6,680 | Implemented |
NC0277 # 04 Y:2004 | 04 | 2004 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $750 | $782 | Implemented |
NC0277 # 05 Y:2004 | 05 | 2004 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $1,387 | $1,900 | Not Implemented |
NC0277 # 06 Y:2004 | 06 | 2004 | ADJUST BURNERS FOR EFFICIENT OPERATION | $1,049 | $1,000 | Implemented |
MS0241 # 01 Y:2003 | 01 | 2003 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $52,802 | $8,788 | n/a |
MS0241 # 02 Y:2003 | 02 | 2003 | RECOVER WASTE HEAT FROM EQUIPMENT | $25,062 | $2,486 | Not Implemented |
MS0241 # 03 Y:2003 | 03 | 2003 | OPTIMIZE PLANT POWER FACTOR | $30,220 | $20,410 | Implemented |
MS0241 # 04 Y:2003 | 04 | 2003 | REPAIR AND ELIMINATE STEAM LEAKS | $11,644 | $760 | Implemented |
MS0241 # 05 Y:2003 | 05 | 2003 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $6,378 | $129 | Implemented |
MS0241 # 06 Y:2003 | 06 | 2003 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,721 | $7,328 | Not Implemented |
MS0241 # 07 Y:2003 | 07 | 2003 | RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS | $3,613 | $0 | Implemented |
MS0241 # 08 Y:2003 | 08 | 2003 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $3,103 | $1,102 | Not Implemented |
MS0241 # 09 Y:2003 | 09 | 2003 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,854 | $3,600 | Implemented |
MS0241 # 10 Y:2003 | 10 | 2003 | INSTALL OCCUPANCY SENSORS | $1,004 | $416 | Not Implemented |
MS0241 # 11 Y:2003 | 11 | 2003 | INSTALL TIMERS AND/OR THERMOSTATS | $856 | $1,575 | Not Implemented |