Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
28
matching recommendationsNAICS | 325613 | Surface Active Agent Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UD0832 # 10 Y:2011 | 10 | 2011 | REPAIR OR REPLACE STEAM TRAPS | $14,246 | $2,000 | Not Implemented |
UD0832 # 09 Y:2011 | 09 | 2011 | RECOVER WASTE HEAT FROM EQUIPMENT | $25,624 | $5,000 | Not Implemented |
UD0832 # 08 Y:2011 | 08 | 2011 | USE FLOW CONTROL VALVES ON EQUIPMENT TO OPTIMIZE WATER USE | $5,424 | $500 | Implemented |
UD0832 # 07 Y:2011 | 07 | 2011 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $986 | $500 | Implemented |
UD0832 # 06 Y:2011 | 06 | 2011 | UPGRADE OBSOLETE EQUIPMENT | $4,243 | $4,728 | Implemented |
UD0832 # 05 Y:2011 | 05 | 2011 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $9,473 | $16,265 | Not Implemented |
UD0832 # 04 Y:2011 | 04 | 2011 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $56,419 | $39,141 | Implemented |
UD0832 # 03 Y:2011 | 03 | 2011 | INSTALL OCCUPANCY SENSORS | $1,977 | $1,063 | Implemented |
UD0832 # 02 Y:2011 | 02 | 2011 | DISCONNECT BALLASTS | $2,570 | $250 | Implemented |
UD0832 # 01 Y:2011 | 01 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $14,751 | $40,000 | Implemented |
UD0832 # 11 Y:2011 | 11 | 2011 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $11,335 | $2,620 | Not Implemented |
UD0832 # 12 Y:2011 | 12 | 2011 | RECOVER WASTE HEAT FROM EQUIPMENT | $2,554 | $5,000 | Not Implemented |
UD0736 # 14 Y:2006 | 14 | 2006 | UPGRADE CONTROLS ON COMPRESSORS | $4,542 | $0 | Not Implemented |
UD0736 # 01 Y:2006 | 01 | 2006 | REPLACE EXISTING EQUIPMENT WITH MORE SUITABLE SUBSTITUTES | $511,635 | $1,058,400 | Not Implemented |
UD0736 # 13 Y:2006 | 13 | 2006 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $7,098 | $0 | Implemented |
UD0736 # 12 Y:2006 | 12 | 2006 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $9,612 | $26,000 | Implemented |
UD0736 # 11 Y:2006 | 11 | 2006 | TREAT AND REUSE RINSE WATERS | $9,788 | $10,000 | Not Implemented |
UD0736 # 10 Y:2006 | 10 | 2006 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $9,947 | $15,000 | Not Implemented |
UD0736 # 09 Y:2006 | 09 | 2006 | REPAIR OR REPLACE STEAM TRAPS | $11,892 | $240 | Implemented |
UD0736 # 08 Y:2006 | 08 | 2006 | INSULATE FEEDWATER TANK | $12,187 | $6,825 | Implemented |
UD0736 # 07 Y:2006 | 07 | 2006 | INSULATE BARE EQUIPMENT | $14,596 | $6,878 | Not Implemented |
UD0736 # 06 Y:2006 | 06 | 2006 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $29,264 | $40,000 | Implemented |
UD0736 # 05 Y:2006 | 05 | 2006 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $32,384 | $28,000 | Implemented |
UD0736 # 04 Y:2006 | 04 | 2006 | INSTALL / REPAIR INSULATION ON STEAM LINES | $35,184 | $14,041 | Implemented |
UD0736 # 03 Y:2006 | 03 | 2006 | REPAIR AND ELIMINATE STEAM LEAKS | $36,074 | $28,000 | Implemented |