IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

64

matching recommendations
Reset
NAICS 325998 All Other Miscellaneous Chemical Product and Preparation Manufacturing
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
LS0005 # 04 Y:2017 04 2017 TURN OFF EQUIPMENT WHEN NOT IN USE $7,832 $100 Implemented
LS0005 # 05 Y:2017 05 2017 INSTALL SMALLER BOILER (INCREASE HIGH FIRE DUTY CYCLE) $134,326 $621,739 Not Implemented
LS0005 # 06 Y:2017 06 2017 CLEAN OR COLOR ROOF TO REDUCE SOLAR LOAD $7,044 $34,056 Not Implemented
LS0005 # 07 Y:2017 07 2017 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $6,997 $3,280 Implemented
LS0005 # 08 Y:2017 08 2017 INSTALL TIMERS AND/OR THERMOSTATS $330 $400 Implemented
LS0005 # 09 Y:2017 09 2017 INSTALL OCCUPANCY SENSORS $347 $585 Implemented
LS0005 # 01 Y:2017 01 2017 OPTIMIZE PLANT POWER FACTOR $69,401 $106,209 Not Implemented
LL0332 # 07 Y:2010 07 2010 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $110 $90 Implemented
LL0332 # 06 Y:2010 06 2010 INSTALL OCCUPANCY SENSORS $115 $300 Not Implemented
LL0332 # 05 Y:2010 05 2010 CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES $372 $156 Implemented
LL0332 # 04 Y:2010 04 2010 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $477 $30 Implemented
LL0332 # 03 Y:2010 03 2010 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $658 $350 Implemented
LL0332 # 02 Y:2010 02 2010 REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS $3,014 $450 Implemented
LL0332 # 01 Y:2010 01 2010 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $3,186 $1,815 Implemented
LL0307 # 01 Y:2009 01 2009 INSULATE BARE EQUIPMENT $8,550 $1,841 Implemented
LL0307 # 02 Y:2009 02 2009 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $7,776 $6,070 Not Implemented
LL0307 # 03 Y:2009 03 2009 REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS $3,201 $64 Not Implemented
LL0307 # 04 Y:2009 04 2009 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $2,773 $870 Implemented
LL0307 # 05 Y:2009 05 2009 BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE $2,650 $180 Implemented
LL0307 # 07 Y:2009 07 2009 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $948 $10 Not Implemented
LL0307 # 08 Y:2009 08 2009 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $518 $40 Implemented
LL0307 # 09 Y:2009 09 2009 CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES $414 $312 Not Implemented
LL0307 # 06 Y:2009 06 2009 INSTALL TIMERS ON LIGHT SWITCHES IN LITTLE USED AREAS $2,164 $45 Not Implemented
LL0245 # 04 Y:2006 04 2006 INSULATE BARE EQUIPMENT $185,638 $4,644 Not Implemented
LL0245 # 01 Y:2006 01 2006 ESTABLISH BURNER MAINTENANCE SCHEDULE FOR BOILERS $3,334,582 $60,000 Implemented