Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
134
matching recommendationsNAICS | 326 | Plastics and Rubber Products Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
OK0929 # 03 Y:2015 | 03 | 2015 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $82,236 | $72,000 | Not Implemented |
OK0929 # 01 Y:2015 | 01 | 2015 | OPTIMIZE PLANT POWER FACTOR | $26,164 | $68,769 | Not Implemented |
OK0921 # 05 Y:2015 | 05 | 2015 | REDUCE FLUID FLOW RATES | $32,332 | $5,000 | Implemented |
OK0921 # 01 Y:2015 | 01 | 2015 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $7,838 | $28,060 | Implemented |
OK0921 # 02 Y:2015 | 02 | 2015 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $12,026 | $832 | Not Implemented |
OK0921 # 03 Y:2015 | 03 | 2015 | INSULATE BARE EQUIPMENT | $13,915 | $4,348 | Implemented |
OK0921 # 04 Y:2015 | 04 | 2015 | INSTALL DESICCANT HUMIDITY CONTROL SYSTEM | $89,313 | $72,000 | Implemented |
OK0863 # 01 Y:2013 | 01 | 2013 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $14,703 | $2,500 | Not Implemented |
OK0863 # 03 Y:2013 | 03 | 2013 | INSTALL OCCUPANCY SENSORS | $3,208 | $4,450 | Not Implemented |
OK0863 # 02 Y:2013 | 02 | 2013 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $8,069 | $22,428 | Not Implemented |
OK0863 # 04 Y:2013 | 04 | 2013 | INSULATE BARE EQUIPMENT | $10,721 | $1,250 | Not Implemented |
TT0113 # 05 Y:2013 | 05 | 2013 | INSTALL OCCUPANCY SENSORS | $14,759 | $20,200 | Not Implemented |
TT0113 # 04 Y:2013 | 04 | 2013 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $135 | $114 | Not Implemented |
TT0113 # 03 Y:2013 | 03 | 2013 | DISCONNECT BALLASTS | $1,433 | $0 | Not Implemented |
TT0113 # 02 Y:2013 | 02 | 2013 | INSULATE BARE EQUIPMENT | $29,010 | $0 | Not Implemented |
TT0113 # 01 Y:2013 | 01 | 2013 | REMOVE OR CLOSE OFF UNNEEDED COMPRESSED AIR LINES | $12,194 | $0 | Not Implemented |
TT0113 # 07 Y:2013 | 07 | 2013 | UPGRADE CONTROLS ON COMPRESSORS | $2,195 | $5,600 | Not Implemented |
TT0113 # 06 Y:2013 | 06 | 2013 | DEVELOP A REPAIR/REPLACE POLICY | $21,613 | $30,289 | Not Implemented |
OK0825 # 01 Y:2012 | 01 | 2012 | REPLACE BOILER | $228,516 | $1,085,000 | Not Implemented |
OK0825 # 03 Y:2012 | 03 | 2012 | INSTALL OCCUPANCY SENSORS | $194 | $3,150 | Not Implemented |
OK0825 # 10 Y:2012 | 10 | 2012 | INSTALL SET-BACK TIMERS | $929 | $937 | Not Implemented |
OK0825 # 09 Y:2012 | 09 | 2012 | SEPARATE CONTROLS OF AIR HANDLERS FROM AC/ HEATING SYSTEMS | $15,683 | $15,683 | Not Implemented |
OK0825 # 04 Y:2012 | 04 | 2012 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $19,699 | $65,000 | Not Implemented |
OK0825 # 07 Y:2012 | 07 | 2012 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $2,300 | $450 | Not Implemented |
OK0825 # 11 Y:2012 | 11 | 2012 | INSULATE GLAZING, WALLS, CEILINGS, AND ROOFS | $8,292 | $406,800 | Not Implemented |