IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

8,415

matching recommendations
Reset
NAICS 326 Plastics and Rubber Products Manufacturing
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
LL0193 # 01 Y:2004 01 2004 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $118,511 $3,400 Implemented
LL0193 # 02 Y:2004 02 2004 OPTIMIZE PLANT POWER FACTOR $16,033 $25,871 Implemented
LL0193 # 03 Y:2004 03 2004 INSTALL TIMERS ON LIGHT SWITCHES IN LITTLE USED AREAS $12,157 $1,671 Not Implemented
LL0193 # 04 Y:2004 04 2004 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $4,526 $390 Implemented
LL0193 # 05 Y:2004 05 2004 INSTALL OCCUPANCY SENSORS $195 $135 Implemented
LL0193 # 06 Y:2004 06 2004 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $468 $350 Implemented
LL0193 # 07 Y:2004 07 2004 BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE $4,980 $1,684 Implemented
LM0079 # 01 Y:2004 01 2004 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $4,448 $410 Not Implemented
LM0079 # 02 Y:2004 02 2004 DO NOT USE COMPRESSED AIR FOR PERSONAL COOLING $846 $30 Not Implemented
LM0079 # 03 Y:2004 03 2004 RE-ARRANGE EQUIPMENT LAYOUT TO REDUCE LABOR COSTS $5,758 $8,250 Not Implemented
LM0079 # 04 Y:2004 04 2004 TRAIN OPERATORS FOR MAXIMUM OPERATING EFFICIENCY $13,000 $3,122 Not Implemented
LM0079 # 05 Y:2004 05 2004 ELIMINATE OLD STOCK AND MODIFY INVENTORY CONTROL $1,045 $0 Not Implemented
OR0458 # 01 Y:2004 01 2004 MODIFY WORKLOAD $60,800 $480 Not Implemented
OR0458 # 02 Y:2004 02 2004 OPTIMIZE PLANT POWER FACTOR $9,440 $7,400 Not Implemented
OR0458 # 03 Y:2004 03 2004 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $7,200 $4,600 Not Implemented
OR0458 # 04 Y:2004 04 2004 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $6,300 $6,000 Not Implemented
OR0458 # 05 Y:2004 05 2004 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $2,800 $0 Not Implemented
OR0458 # 06 Y:2004 06 2004 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $4,880 $3,000 Not Implemented
UF0344 # 01 Y:2004 01 2004 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $21,466 $60,000 Not Implemented
UF0344 # 02 Y:2004 02 2004 TURN OFF EQUIPMENT WHEN NOT IN USE $11,821 $0 Not Implemented
UF0344 # 03 Y:2004 03 2004 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $2,950 $490 Implemented
UF0344 # 04 Y:2004 04 2004 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $2,898 $0 Not Implemented
UF0344 # 05 Y:2004 05 2004 USE PHOTOCELL CONTROLS $1,795 $6,164 Not Implemented
UF0344 # 06 Y:2004 06 2004 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $1,470 $150 Not Implemented
UF0344 # 07 Y:2004 07 2004 METER WASTE WATER $2,616 $1,500 Not Implemented