Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
278
matching recommendationsNAICS | 326 | Plastics and Rubber Products Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
OK0855 # 18 Y:2013 | 18 | 2013 | INSULATE BARE EQUIPMENT | $258 | $960 | Not Implemented |
OK0855 # 19 Y:2013 | 19 | 2013 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $4,292 | $6,796 | Not Implemented |
OK0855 # 20 Y:2013 | 20 | 2013 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $1,823 | $3,063 | Not Implemented |
OK0855 # 21 Y:2013 | 21 | 2013 | OPTIMIZE PLANT POWER FACTOR | $17,798 | $13,508 | Implemented |
OK0806 # 01 Y:2011 | 01 | 2011 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $109,231 | $57,500 | Not Implemented |
OK0806 # 02 Y:2011 | 02 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $10,484 | $37,707 | Implemented |
OK0806 # 03 Y:2011 | 03 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $7,177 | $38,005 | Implemented |
OK0806 # 04 Y:2011 | 04 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,415 | $7,724 | Implemented |
OK0806 # 05 Y:2011 | 05 | 2011 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $5,172 | $1,600 | Implemented |
OK0806 # 06 Y:2011 | 06 | 2011 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $2,602 | $414 | Implemented |
OK0806 # 07 Y:2011 | 07 | 2011 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $8,222 | $870 | Not Implemented |
OK0806 # 08 Y:2011 | 08 | 2011 | INSULATE BARE EQUIPMENT | $6,859 | $2,964 | Not Implemented |
OK0806 # 09 Y:2011 | 09 | 2011 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $2,676 | $7,130 | Not Implemented |
OK0777 # 01 Y:2009 | 01 | 2009 | USE COOLING TOWER WATER INSTEAD OF REFRIGERATION | $164,328 | $490,000 | Implemented |
OK0777 # 02 Y:2009 | 02 | 2009 | CHILL WATER TO THE HIGHEST TEMPERATURE POSSIBLE | $26,234 | $0 | Implemented |
OK0777 # 03 Y:2009 | 03 | 2009 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,889 | $19,448 | Not Implemented |
OK0777 # 04 Y:2009 | 04 | 2009 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $2,136 | $3,129 | Implemented |
OK0777 # 05 Y:2009 | 05 | 2009 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $28,753 | $33,300 | Implemented |
OK0777 # 06 Y:2009 | 06 | 2009 | INSTALL TIMERS AND/OR THERMOSTATS | $2,638 | $779 | Implemented |
OK0764 # 01 Y:2008 | 01 | 2008 | RECOVER WASTE HEAT FROM EQUIPMENT | $3,109 | $5,086 | Not Implemented |
OK0764 # 02 Y:2008 | 02 | 2008 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,596 | $14,878 | Not Implemented |
OK0764 # 03 Y:2008 | 03 | 2008 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $477 | $1,165 | Not Implemented |
OK0764 # 04 Y:2008 | 04 | 2008 | INSTALL / REPAIR INSULATION ON STEAM LINES | $22,038 | $14,300 | Not Implemented |
OK0764 # 05 Y:2008 | 05 | 2008 | BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE | $7,000 | $0 | Not Implemented |
OK0764 # 06 Y:2008 | 06 | 2008 | CLOSE OFF UNNEEDED STEAM LINES | $7,161 | $0 | Not Implemented |