Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
763
matching recommendationsNAICS | 3261 | Plastics Product Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UD0820 # 13 Y:2010 | 13 | 2010 | REPLACE AIR CURTAIN DOORS WITH SOLID DOORS | $7,994 | $45,000 | Not Implemented |
UD0820 # 14 Y:2010 | 14 | 2010 | USE RADIANT HEATER FOR SPOT HEATING | $4,962 | $4,550 | Implemented |
UD0816 # 01 Y:2010 | 01 | 2010 | OPTIMIZE PLANT POWER FACTOR | $2,978 | $0 | Not Implemented |
UD0816 # 02 Y:2010 | 02 | 2010 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $1,468 | $0 | Implemented |
UD0816 # 03 Y:2010 | 03 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $17,881 | $0 | Implemented |
UD0816 # 04 Y:2010 | 04 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $8,929 | $0 | Implemented |
UD0816 # 05 Y:2010 | 05 | 2010 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $4,108 | $0 | Implemented |
UD0816 # 06 Y:2010 | 06 | 2010 | INSULATE BARE EQUIPMENT | $22,144 | $0 | Implemented |
UD0816 # 07 Y:2010 | 07 | 2010 | INSULATE BARE EQUIPMENT | $346 | $0 | Not Implemented |
UD0816 # 08 Y:2010 | 08 | 2010 | INSULATE BARE EQUIPMENT | $6,179 | $0 | Not Implemented |
UD0816 # 09 Y:2010 | 09 | 2010 | UTILIZE A LESS EXPENSIVE COOLING METHOD | $15,412 | $0 | Implemented |
UD0816 # 10 Y:2010 | 10 | 2010 | CHILL WATER TO THE HIGHEST TEMPERATURE POSSIBLE | $3,601 | $0 | Not Implemented |
UD0816 # 11 Y:2010 | 11 | 2010 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $7,426 | $0 | Implemented |
UD0816 # 12 Y:2010 | 12 | 2010 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $4,512 | $0 | Implemented |
UD0816 # 13 Y:2010 | 13 | 2010 | USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING | $1,524 | $0 | Not Implemented |
UD0816 # 14 Y:2010 | 14 | 2010 | INSTALL TIMERS AND/OR THERMOSTATS | $10,027 | $0 | Not Implemented |
UD0816 # 15 Y:2010 | 15 | 2010 | CLOSE HOLES AND OPENINGS IN BUILDING SUCH AS BROKEN WINDOWS | $1,123 | $0 | Not Implemented |
UD0816 # 16 Y:2010 | 16 | 2010 | INSULATE GLAZING, WALLS, CEILINGS, AND ROOFS | $766 | $0 | Not Implemented |
UD0809 # 01 Y:2009 | 01 | 2009 | RECYCLE AIR FOR HEATING, VENTILATION AND AIR CONDITIONING | $22,565 | $5,640 | Implemented |
UD0809 # 02 Y:2009 | 02 | 2009 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $20,495 | $120,000 | Implemented |
UD0809 # 03 Y:2009 | 03 | 2009 | OPTIMIZE PLANT POWER FACTOR | $15,628 | $20,000 | Not Implemented |
UD0809 # 04 Y:2009 | 04 | 2009 | TURN OFF EQUIPMENT WHEN NOT IN USE | $8,423 | $0 | Implemented |
UD0809 # 05 Y:2009 | 05 | 2009 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $6,288 | $324 | Not Implemented |
UD0809 # 06 Y:2009 | 06 | 2009 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $5,845 | $1,000 | Not Implemented |
UD0809 # 07 Y:2009 | 07 | 2009 | TURN OFF EQUIPMENT WHEN NOT IN USE | $4,812 | $0 | Not Implemented |