Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
7,072
matching recommendationsNAICS | 3261 | Plastics Product Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UD0809 # 14 Y:2009 | 14 | 2009 | UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT | $2,678 | $5,467 | Not Implemented |
UD0809 # 15 Y:2009 | 15 | 2009 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $685 | $0 | Not Implemented |
UD0809 # 16 Y:2009 | 16 | 2009 | DISCONNECT BALLASTS | $532 | $0 | Not Implemented |
UD0809 # 17 Y:2009 | 17 | 2009 | TURN OFF EQUIPMENT WHEN NOT IN USE | $414 | $0 | Implemented |
UD0809 # 18 Y:2009 | 18 | 2009 | CHILL WATER TO THE HIGHEST TEMPERATURE POSSIBLE | $363 | $0 | Not Implemented |
UD0809 # 19 Y:2009 | 19 | 2009 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $181 | $500 | Not Implemented |
MZ0043 # 01 Y:2009 | 01 | 2009 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,595 | $20,400 | Implemented |
MZ0043 # 02 Y:2009 | 02 | 2009 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,634 | $860 | Implemented |
MZ0043 # 03 Y:2009 | 03 | 2009 | INSTALL OCCUPANCY SENSORS | $2,319 | $480 | Implemented |
MZ0043 # 04 Y:2009 | 04 | 2009 | USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE | $627 | $1,800 | Implemented |
MZ0043 # 05 Y:2009 | 05 | 2009 | USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE | $7,387 | $3,600 | Implemented |
MZ0043 # 06 Y:2009 | 06 | 2009 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $3,995 | $1 | Implemented |
MZ0043 # 07 Y:2009 | 07 | 2009 | RECOVER WASTE HEAT FROM EQUIPMENT | $3,009 | $500 | Not Implemented |
MZ0043 # 08 Y:2009 | 08 | 2009 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $192,075 | $12,080 | Implemented |
MZ0043 # 09 Y:2009 | 09 | 2009 | MOVE BOILER TO MORE EFFICIENT LOCATION | $10,937 | $3,000 | Implemented |
LL0321 # 01 Y:2009 | 01 | 2009 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $26,101 | $6,360 | Implemented |
LL0321 # 02 Y:2009 | 02 | 2009 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $11,987 | $30 | Implemented |
LL0321 # 03 Y:2009 | 03 | 2009 | INSULATE BARE EQUIPMENT | $3,253 | $4,564 | Implemented |
LL0321 # 04 Y:2009 | 04 | 2009 | INSULATE BARE EQUIPMENT | $1,366 | $734 | Implemented |
LL0321 # 05 Y:2009 | 05 | 2009 | CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES | $802 | $779 | Not Implemented |
LL0321 # 06 Y:2009 | 06 | 2009 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $797 | $55 | Not Implemented |
UD0807 # 01 Y:2009 | 01 | 2009 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $11,275 | $2,000 | Implemented |
UD0807 # 02 Y:2009 | 02 | 2009 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $4,575 | $1,000 | Implemented |
UD0807 # 03 Y:2009 | 03 | 2009 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $65,548 | $15,550 | Not Implemented |
UD0807 # 04 Y:2009 | 04 | 2009 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,604 | $1,000 | Not Implemented |