Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
7,072
matching recommendationsNAICS | 3261 | Plastics Product Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
NC0276 # 03 Y:2004 | 03 | 2004 | USE FIXTURES TO REDUCE MACHINE CHANGEOUT TIMES | $18,000 | $8,050 | Implemented |
NC0276 # 04 Y:2004 | 04 | 2004 | INSULATE BARE EQUIPMENT | $14,713 | $3,487 | Not Implemented |
NC0276 # 05 Y:2004 | 05 | 2004 | DEVELOP A REPAIR/REPLACE POLICY | $1,432 | $1,085 | Implemented |
NC0276 # 06 Y:2004 | 06 | 2004 | USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING | $4,405 | $5,000 | Not Implemented |
NC0276 # 07 Y:2004 | 07 | 2004 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,023 | $1,170 | Implemented |
LL0181 # 01 Y:2004 | 01 | 2004 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $3,934 | $395 | Implemented |
LL0181 # 02 Y:2004 | 02 | 2004 | INSULATE BARE EQUIPMENT | $3,194 | $1,013 | Implemented |
LL0181 # 03 Y:2004 | 03 | 2004 | INSTALL TIMERS AND/OR THERMOSTATS | $2,927 | $1,805 | Not Implemented |
LL0181 # 04 Y:2004 | 04 | 2004 | USE PHOTOCELL CONTROLS | $2,594 | $420 | Not Implemented |
LL0181 # 05 Y:2004 | 05 | 2004 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,565 | $1,015 | Implemented |
LL0181 # 06 Y:2004 | 06 | 2004 | INSTALL OCCUPANCY SENSORS | $657 | $135 | Not Implemented |
LL0181 # 07 Y:2004 | 07 | 2004 | BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE | $210 | $165 | Implemented |
BD0251 # 01 Y:2004 | 01 | 2004 | INSULATE BARE EQUIPMENT | $32,333 | $98,853 | n/a |
BD0251 # 02 Y:2004 | 02 | 2004 | SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY | $8,924 | $8,924 | Not Implemented |
BD0251 # 03 Y:2004 | 03 | 2004 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $7,487 | $850 | Not Implemented |
BD0251 # 04 Y:2004 | 04 | 2004 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $7,149 | $945 | Not Implemented |
BD0251 # 05 Y:2004 | 05 | 2004 | RECOVER WASTE HEAT FROM EQUIPMENT | $4,899 | $750 | Not Implemented |
BD0251 # 06 Y:2004 | 06 | 2004 | INSULATE BARE EQUIPMENT | $4,625 | $413 | Not Implemented |
BD0251 # 07 Y:2004 | 07 | 2004 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,870 | $10,160 | n/a |
BD0251 # 08 Y:2004 | 08 | 2004 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $2,779 | $2,000 | Not Implemented |
BD0251 # 09 Y:2004 | 09 | 2004 | USE SYNTHETIC LUBRICANT | $2,224 | $1,200 | Not Implemented |
BD0251 # 10 Y:2004 | 10 | 2004 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $2,106 | $3,570 | Not Implemented |
BD0251 # 11 Y:2004 | 11 | 2004 | INSTALL OCCUPANCY SENSORS | $1,202 | $2,670 | Not Implemented |
BD0251 # 12 Y:2004 | 12 | 2004 | INSTALL OCCUPANCY SENSORS | $1,199 | $2,100 | Not Implemented |
BD0251 # 13 Y:2004 | 13 | 2004 | USE PHOTOCELL CONTROLS | $767 | $650 | Not Implemented |