Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
7,061
matching recommendationsNAICS | 3261 | Plastics Product Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UF0318 # 04 Y:2003 | 04 | 2003 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $2,439 | $2,619 | Not Implemented |
UF0318 # 05 Y:2003 | 05 | 2003 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,202 | $0 | Implemented |
UF0318 # 06 Y:2003 | 06 | 2003 | INSTALL OCCUPANCY SENSORS | $1,117 | $852 | Not Implemented |
UF0318 # 07 Y:2003 | 07 | 2003 | UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT | $11,077 | $16,791 | Not Implemented |
UF0318 # 08 Y:2003 | 08 | 2003 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $3,449 | $0 | Implemented |
UF0318 # 09 Y:2003 | 09 | 2003 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $8,037 | $13,339 | Implemented |
UF0318 # 10 Y:2003 | 10 | 2003 | INSTALL TIMERS ON LIGHT SWITCHES IN LITTLE USED AREAS | $2,364 | $2,358 | Not Implemented |
UF0318 # 11 Y:2003 | 11 | 2003 | MAINTAIN MACHINES TO REDUCE LEAKS | $77,760 | $14,000 | Implemented |
UF0318 # 12 Y:2003 | 12 | 2003 | TRAIN OPERATORS FOR MAXIMUM OPERATING EFFICIENCY | $12,000 | $8,200 | Implemented |
WV0259 # 01 Y:2003 | 01 | 2003 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $217 | $450 | Implemented |
WV0259 # 02 Y:2003 | 02 | 2003 | USE OPTIMUM THICKNESS INSULATION | $2,207 | $375 | Not Implemented |
WV0259 # 03 Y:2003 | 03 | 2003 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $6,449 | $10,381 | Implemented |
WV0259 # 04 Y:2003 | 04 | 2003 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $144 | $136 | Implemented |
WV0259 # 05 Y:2003 | 05 | 2003 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,897 | $50 | Implemented |
WV0259 # 06 Y:2003 | 06 | 2003 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $494 | $185 | Not Implemented |
WV0259 # 07 Y:2003 | 07 | 2003 | USE MOST EFFICIENT EQUIPMENT AT IT'S MAXIMUM CAPACITY AND LESS EFFICIENT EQUIPMENT ONLY WHEN NECESSARY | $3,930 | $250 | Implemented |
WV0259 # 08 Y:2003 | 08 | 2003 | INSULATE BARE EQUIPMENT | $12,370 | $1,015 | Not Implemented |
WV0259 # 09 Y:2003 | 09 | 2003 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $5,414 | $420 | Not Implemented |
WV0259 # 10 Y:2003 | 10 | 2003 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,727 | $250 | Implemented |
WV0259 # 11 Y:2003 | 11 | 2003 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $6,126 | $800 | Implemented |
WV0259 # 12 Y:2003 | 12 | 2003 | CHILL WATER TO THE HIGHEST TEMPERATURE POSSIBLE | $217 | $50 | Implemented |
MI0053 # 01 Y:2003 | 01 | 2003 | METER WASTE WATER | $1,881 | $1,454 | Not Implemented |
MI0053 # 02 Y:2003 | 02 | 2003 | BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE | $35,000 | $7,660 | Implemented |
MI0053 # 03 Y:2003 | 03 | 2003 | RE-USE OR RECYCLE HOT OR COLD PROCESS EXHAUST AIR | $4,563 | $654 | Not Implemented |
MI0053 # 04 Y:2003 | 04 | 2003 | INSTALL OCCUPANCY SENSORS | $7,089 | $885 | Not Implemented |