Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

69

matching recommendations
Reset
NAICS 3261 Plastics Product Manufacturing
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
MS0249 # 10 Y:2004 10 2004 INSTALL OCCUPANCY SENSORS $949 $519 Not Implemented
MS0249 # 11 Y:2004 11 2004 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $488 $820 Implemented
MS0249 # 07 Y:2004 07 2004 RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS $2,064 $0 Not Implemented
MS0231 # 07 Y:2003 07 2003 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $5,254 $8,386 Not Implemented
MS0231 # 01 Y:2003 01 2003 OPTIMIZE PLANT POWER FACTOR $89,273 $191,565 Implemented
MS0231 # 02 Y:2003 02 2003 PREHEAT COMBUSTION AIR WITH WASTE HEAT $30,273 $4,486 Not Implemented
MS0231 # 03 Y:2003 03 2003 USE SYNTHETIC LUBRICANT $13,851 $7,500 Not Implemented
MS0231 # 04 Y:2003 04 2003 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $15,508 $26,644 Not Implemented
MS0231 # 05 Y:2003 05 2003 INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT $8,811 $11,139 Not Implemented
MS0231 # 06 Y:2003 06 2003 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $5,964 $3,200 Not Implemented
MS0231 # 08 Y:2003 08 2003 USE RADIANT HEATER FOR SPOT HEATING $3,584 $3,456 Implemented
MS0231 # 09 Y:2003 09 2003 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $995 $2,905 Not Implemented
MS0231 # 10 Y:2003 10 2003 INSTALL TIMERS AND/OR THERMOSTATS $152 $119 Implemented
MS0231 # 11 Y:2003 11 2003 CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE $120 $10 Implemented
MS0226 # 01 Y:2003 01 2003 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $18,996 $0 Not Implemented
MS0226 # 05 Y:2003 05 2003 INSTALL TIMERS AND/OR THERMOSTATS $886 $591 Not Implemented
MS0226 # 04 Y:2003 04 2003 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $2,417 $205 Implemented
MS0226 # 03 Y:2003 03 2003 INSULATE BARE EQUIPMENT $2,660 $1,669 Not Implemented
MS0226 # 02 Y:2003 02 2003 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $4,859 $2,372 Implemented