Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
328
matching recommendationsNAICS | 3261 | Plastics Product Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
IP0028 # 01 Y:2014 | 01 | 2014 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $545 | $0 | Implemented |
IP0028 # 02 Y:2014 | 02 | 2014 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $216 | $13 | Implemented |
IP0028 # 03 Y:2014 | 03 | 2014 | INSTALL SET-BACK TIMERS | $1,201 | $196 | Implemented |
IP0028 # 04 Y:2014 | 04 | 2014 | INSTALL OCCUPANCY SENSORS | $147 | $76 | Implemented |
IP0028 # 05 Y:2014 | 05 | 2014 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $282 | $357 | Implemented |
IP0028 # 06 Y:2014 | 06 | 2014 | INSULATE BARE EQUIPMENT | $655 | $2,312 | Not Implemented |
IP0028 # 07 Y:2014 | 07 | 2014 | REPAIR FURNACES AND OVEN DOORS SO THAT THEY SEAL EFFICIENTLY | $1,354 | $5,025 | Not Implemented |
IP0025 # 01 Y:2014 | 01 | 2014 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $6,805 | $0 | Not Implemented |
IP0025 # 02 Y:2014 | 02 | 2014 | APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES | $8,161 | $0 | Not Implemented |
IP0025 # 03 Y:2014 | 03 | 2014 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $471 | $0 | Not Implemented |
IP0025 # 04 Y:2014 | 04 | 2014 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $4,545 | $0 | Not Implemented |
IP0025 # 05 Y:2014 | 05 | 2014 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $4,759 | $60 | Not Implemented |
IP0025 # 06 Y:2014 | 06 | 2014 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,468 | $0 | Not Implemented |
IP0025 # 07 Y:2014 | 07 | 2014 | INSULATE BARE EQUIPMENT | $2,123 | $1,770 | Not Implemented |
IP0025 # 08 Y:2014 | 08 | 2014 | INSTALL OCCUPANCY SENSORS | $2,944 | $3,961 | Not Implemented |
UD0852 # 09 Y:2012 | 09 | 2012 | USE SOLAR HEAT TO MAKE ELECTRICTY | $27,604 | $106,738 | Not Implemented |
UD0852 # 01 Y:2012 | 01 | 2012 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $156,438 | $342,000 | Not Implemented |
UD0852 # 02 Y:2012 | 02 | 2012 | REDUCE TEMPERATURE OF PROCESS EQUIPMENT WHEN ON STANDBY | $13,731 | $8,250 | Not Implemented |
UD0852 # 03 Y:2012 | 03 | 2012 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,349 | $0 | Implemented |
UD0852 # 04 Y:2012 | 04 | 2012 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $41,934 | $6,000 | Implemented |
UD0852 # 05 Y:2012 | 05 | 2012 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $4,072 | $1,000 | Implemented |
UD0852 # 06 Y:2012 | 06 | 2012 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $2,716 | $5,000 | Not Implemented |
UD0852 # 07 Y:2012 | 07 | 2012 | INSULATE BARE EQUIPMENT | $94,327 | $190,000 | Not Implemented |
UD0852 # 08 Y:2012 | 08 | 2012 | USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING | $15,333 | $50,000 | Implemented |
UD0814 # 05 Y:2010 | 05 | 2010 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $386 | $0 | Implemented |