Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

353

matching recommendations
Reset
NAICS 3261 Plastics Product Manufacturing
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
LE0372 # 08 Y:2014 08 2014 INSTALL TIMERS AND/OR THERMOSTATS $645 $711 Implemented
LE0372 # 09 Y:2014 09 2014 RE-USE OR RECYCLE HOT OR COLD PROCESS EXHAUST AIR $24,930 $41,000 Not Implemented
LE0372 # 10 Y:2014 10 2014 USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING $7,402 $13,500 Not Implemented
LE0372 # 11 Y:2014 11 2014 REPLACE OBSOLETE BURNERS WITH MORE EFFICIENT ONES $9,045 $16,500 Implemented
LE0372 # 12 Y:2014 12 2014 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $96 $210 Not Implemented
LE0372 # 13 Y:2014 13 2014 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $3,361 $7,792 Not Implemented
LE0372 # 14 Y:2014 14 2014 INSTALL / REPAIR INSULATION ON STEAM LINES $2,482 $4,118 Not Implemented
LE0372 # 15 Y:2014 15 2014 REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL $13,408 $64,631 Not Implemented
DL0108 # 01 Y:2013 01 2013 TURN OFF EQUIPMENT WHEN NOT IN USE $39,709 $0 Implemented
DL0108 # 02 Y:2013 02 2013 ADJUST VENTS TO MINIMIZE ENERGY USE $3,279 $0 Not Implemented
DL0108 # 03 Y:2013 03 2013 UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED $13,367 $0 Implemented
DL0108 # 04 Y:2013 04 2013 UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED $1,687 $270 Implemented
DL0108 # 05 Y:2013 05 2013 INSTALL TIMERS AND/OR THERMOSTATS $500 $200 Implemented
DL0108 # 06 Y:2013 06 2013 RE-USE OR RECYCLE HOT OR COLD PROCESS EXHAUST AIR $2,400 $400 Not Implemented
DL0108 # 07 Y:2013 07 2013 USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE $543 $0 Implemented
DL0108 # 08 Y:2013 08 2013 USE LESS TOXIC AND VOLATILE SOLVENT SUBSTITUTES $186,000 $500,000 Not Implemented
LE0343 # 01 Y:2012 01 2012 USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING $50,414 $67,000 Not Implemented
LE0343 # 02 Y:2012 02 2012 REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL $167,678 $90,000 Not Implemented
LE0343 # 03 Y:2012 03 2012 REPAIR OR REPLACE STEAM TRAPS $14,506 $4,200 Not Implemented
LE0343 # 04 Y:2012 04 2012 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $4,536 $1,000 Not Implemented
LE0343 # 05 Y:2012 05 2012 CLEAN OR COLOR ROOF TO REDUCE SOLAR LOAD $1,380 $6,630 Not Implemented
LE0343 # 06 Y:2012 06 2012 PREHEAT COMBUSTION AIR WITH WASTE HEAT $3,932 $6,000 Not Implemented
LE0343 # 07 Y:2012 07 2012 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $6,100 $16,000 Not Implemented
WV0426 # 10 Y:2011 10 2011 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $723 $21 Implemented
WV0426 # 11 Y:2011 11 2011 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $538 $1,956 Not Implemented