Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
928
matching recommendationsNAICS | 32612 | Plastics Pipe, Pipe Fitting, and Unlaminated Profile Shape Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UD0895 # 02 Y:2014 | 02 | 2014 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $21,208 | $0 | Implemented |
UD0895 # 03 Y:2014 | 03 | 2014 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $48,509 | $7,500 | Implemented |
UD0895 # 04 Y:2014 | 04 | 2014 | KEEP DOORS AND WINDOWS SHUT WHEN NOT ON USE | $2,209 | $0 | Implemented |
UD0895 # 05 Y:2014 | 05 | 2014 | ADD AREA LIGHTING SWITCHES | $1,613 | $1,575 | Implemented |
UD0895 # 06 Y:2014 | 06 | 2014 | INSTALL OCCUPANCY SENSORS | $1,252 | $2,900 | Not Implemented |
UD0895 # 07 Y:2014 | 07 | 2014 | UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT | $249 | $510 | Implemented |
UD0895 # 08 Y:2014 | 08 | 2014 | REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL | $6,823 | $16,000 | Implemented |
UD0895 # 09 Y:2014 | 09 | 2014 | SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY | $3,388 | $800 | Implemented |
UD0895 # 10 Y:2014 | 10 | 2014 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $2,520 | $4,275 | Implemented |
TT0121 # 01 Y:2013 | 01 | 2013 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $5,465 | $100 | Implemented |
TT0121 # 02 Y:2013 | 02 | 2013 | INSTALL OCCUPANCY SENSORS | $2,202 | $2,150 | Not Implemented |
TT0121 # 03 Y:2013 | 03 | 2013 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $47 | $75 | Implemented |
TT0121 # 04 Y:2013 | 04 | 2013 | COMBINE UTILITY METERS | $6,476 | $12,000 | Not Implemented |
TT0121 # 05 Y:2013 | 05 | 2013 | ESTABLISH A PREDICTIVE MAINTENANCE PROGRAM | $4,667 | $9,338 | Not Implemented |
TT0121 # 06 Y:2013 | 06 | 2013 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,685 | $8,460 | Implemented |
TT0121 # 07 Y:2013 | 07 | 2013 | UPGRADE CONTROLS ON COMPRESSORS | $464 | $800 | Implemented |
UM0426 # 01 Y:2013 | 01 | 2013 | USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING | $13,129 | $17,000 | Implemented |
UM0426 # 02 Y:2013 | 02 | 2013 | REPLACE OBSOLETE BURNERS WITH MORE EFFICIENT ONES | $13,400 | $12,000 | Not Implemented |
UM0426 # 03 Y:2013 | 03 | 2013 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $3,910 | $3,500 | Not Implemented |
UM0426 # 04 Y:2013 | 04 | 2013 | INSTALL / REPAIR INSULATION ON STEAM LINES | $1,407 | $1,500 | Implemented |
UM0426 # 05 Y:2013 | 05 | 2013 | RECOVER WASTE HEAT FROM EQUIPMENT | $2,226 | $1,000 | Implemented |
OK0855 # 01 Y:2013 | 01 | 2013 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $14,499 | $9,900 | Not Implemented |
OK0855 # 02 Y:2013 | 02 | 2013 | INSTALL SET-BACK TIMERS | $4,654 | $1,287 | Implemented |
OK0855 # 03 Y:2013 | 03 | 2013 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $2,588 | $9,900 | Not Implemented |
OK0855 # 04 Y:2013 | 04 | 2013 | CLEAN AND MAINTAIN REFRIGERANT CONDENSERS AND TOWERS | $8,807 | $2,070 | Implemented |