Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

238

matching recommendations
Reset
NAICS 326140 Polystyrene Foam Product Manufacturing
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
AM0673 # 08 Y:2015 08 2015 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $347 $40 Not Implemented
AM0673 # 09 Y:2015 09 2015 MINIMIZE OPERATION OF EQUIPMENT MAINTAINED IN STANDBY CONDITION $290 $18 Implemented
AM0673 # 10 Y:2015 10 2015 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $148 $50 Not Implemented
AM0673 # 11 Y:2015 11 2015 MINIMIZE OPERATION OF EQUIPMENT MAINTAINED IN STANDBY CONDITION $22 $0 Implemented
TT0147 # 01 Y:2015 01 2015 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $875 $750 Implemented
TT0147 # 02 Y:2015 02 2015 REPAIR OR REPLACE STEAM TRAPS $5,772 $430 Implemented
TT0147 # 03 Y:2015 03 2015 REPAIR OR REPLACE STEAM TRAPS $1,127 $230 Implemented
TT0147 # 04 Y:2015 04 2015 INSULATE BARE EQUIPMENT $606 $567 Not Implemented
TT0147 # 05 Y:2015 05 2015 INSULATE BARE EQUIPMENT $430 $660 Not Implemented
TT0147 # 06 Y:2015 06 2015 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $1,163 $2,500 Not Implemented
TT0147 # 07 Y:2015 07 2015 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $1,166 $3,000 Not Implemented
TT0147 # 08 Y:2015 08 2015 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $432 $63 Implemented
TT0147 # 09 Y:2015 09 2015 USE PHOTOCELL CONTROLS $151 $90 Implemented
TT0147 # 10 Y:2015 10 2015 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $124 $413 Implemented
TT0147 # 11 Y:2015 11 2015 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $11,330 $16,510 Implemented
DL0133 # 01 Y:2014 01 2014 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $63,690 $134,000 Not Implemented
DL0133 # 02 Y:2014 02 2014 PREHEAT BOILER MAKEUP WATER WITH WASTE PROCESS HEAT $11,540 $18,000 Not Implemented
DL0133 # 03 Y:2014 03 2014 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $10,385 $0 Not Implemented
DL0133 # 04 Y:2014 04 2014 UPGRADE CONTROLS ON COMPRESSORS $7,800 $6,000 Not Implemented
DL0133 # 05 Y:2014 05 2014 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $3,170 $4,000 Not Implemented
DL0133 # 06 Y:2014 06 2014 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $6,710 $26,460 Not Implemented
DL0133 # 07 Y:2014 07 2014 INSTALL AUTOMATIC STACK DAMPER $3,680 $550 Not Implemented
DL0133 # 08 Y:2014 08 2014 RECOVER AND REUSE COOLING WATER $5,180 $15,600 Not Implemented
DL0133 # 09 Y:2014 09 2014 REDUCE VENTILATION AIR $1,110 $0 Not Implemented
DL0133 # 10 Y:2014 10 2014 REDUCE VENTILATION AIR $182 $235 Not Implemented