Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
486
matching recommendationsNAICS | 32619 | Other Plastics Product Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UD0791 # 02 Y:2009 | 02 | 2009 | SHUT OFF STEAM TRAPS ON SUPER HEATED STEAM LINES WHEN NOT IN USE | $66,274 | $0 | Implemented |
UD0791 # 03 Y:2009 | 03 | 2009 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $43,743 | $28,000 | Not Implemented |
UD0791 # 04 Y:2009 | 04 | 2009 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $12,848 | $0 | Implemented |
UD0791 # 05 Y:2009 | 05 | 2009 | PAY BILLS ON TIME TO AVOID LATE FEES | $11,737 | $0 | Implemented |
UD0791 # 06 Y:2009 | 06 | 2009 | INSTALL / REPAIR INSULATION ON STEAM LINES | $11,734 | $2,358 | Not Implemented |
UD0791 # 07 Y:2009 | 07 | 2009 | USE HEAT FROM BOILER BLOWDOWN TO PREHEAT BOILER FEED WATER | $11,202 | $336 | Implemented |
UD0791 # 08 Y:2009 | 08 | 2009 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $9,772 | $15,000 | Not Implemented |
UD0791 # 09 Y:2009 | 09 | 2009 | UPGRADE CONTROLS ON COMPRESSORS | $7,364 | $15,000 | Not Implemented |
UD0791 # 10 Y:2009 | 10 | 2009 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $4,648 | $2,164 | Implemented |
UD0791 # 11 Y:2009 | 11 | 2009 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $2,940 | $8,000 | Not Implemented |
UD0791 # 12 Y:2009 | 12 | 2009 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,512 | $12,625 | Not Implemented |
UD0791 # 13 Y:2009 | 13 | 2009 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,250 | $7,735 | Not Implemented |
UD0791 # 14 Y:2009 | 14 | 2009 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,996 | $6,668 | Not Implemented |
UD0791 # 15 Y:2009 | 15 | 2009 | CLOSE OFF UNNEEDED STEAM LINES | $1,974 | $1,100 | Implemented |
UD0791 # 16 Y:2009 | 16 | 2009 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $924 | $0 | Not Implemented |
UD0791 # 17 Y:2009 | 17 | 2009 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $552 | $1,000 | Implemented |
UD0789 # 01 Y:2009 | 01 | 2009 | USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING | $35,682 | $25,000 | Not Implemented |
UD0789 # 02 Y:2009 | 02 | 2009 | TURN OFF EQUIPMENT WHEN NOT IN USE | $33,134 | $0 | Implemented |
UD0789 # 03 Y:2009 | 03 | 2009 | INSULATE BARE EQUIPMENT | $32,063 | $3,630 | Not Implemented |
UD0789 # 04 Y:2009 | 04 | 2009 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $30,092 | $46,620 | Implemented |
UD0789 # 05 Y:2009 | 05 | 2009 | UPGRADE CONTROLS ON COMPRESSORS | $16,900 | $500 | Implemented |
UD0789 # 06 Y:2009 | 06 | 2009 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $12,888 | $26,100 | Not Implemented |
UD0789 # 07 Y:2009 | 07 | 2009 | OPTIMIZE PLANT POWER FACTOR | $12,305 | $92,000 | Not Implemented |
UD0789 # 08 Y:2009 | 08 | 2009 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $5,410 | $20,400 | Not Implemented |
UD0789 # 09 Y:2009 | 09 | 2009 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,439 | $8,250 | Implemented |