Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
486
matching recommendationsNAICS | 32619 | Other Plastics Product Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
WV0440 # 04 Y:2012 | 04 | 2012 | IMPROVE COMBUSTION CONTROL CAPABILITY | $9,797 | $44,000 | Not Implemented |
WV0440 # 05 Y:2012 | 05 | 2012 | DEVELOP A REPAIR/REPLACE POLICY | $8,028 | $823 | Implemented |
WV0440 # 06 Y:2012 | 06 | 2012 | IMPROVE LUBRICATION PRACTICES | $4,733 | $3,930 | Implemented |
WV0440 # 07 Y:2012 | 07 | 2012 | INSTALL OCCUPANCY SENSORS | $4,089 | $1,440 | Not Implemented |
WV0440 # 08 Y:2012 | 08 | 2012 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $3,442 | $3,000 | Implemented |
WV0440 # 09 Y:2012 | 09 | 2012 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $2,501 | $563 | Not Implemented |
WV0440 # 10 Y:2012 | 10 | 2012 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,414 | $2,980 | Implemented |
WV0440 # 11 Y:2012 | 11 | 2012 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $952 | $1,700 | Not Implemented |
WV0440 # 12 Y:2012 | 12 | 2012 | INSULATE BARE EQUIPMENT | $688 | $599 | Implemented |
WV0440 # 13 Y:2012 | 13 | 2012 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $233 | $60 | Implemented |
WV0435 # 01 Y:2011 | 01 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $10,580 | $26,175 | Not Implemented |
WV0435 # 02 Y:2011 | 02 | 2011 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $7,088 | $2,144 | Implemented |
WV0435 # 03 Y:2011 | 03 | 2011 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $7,062 | $10,480 | Not Implemented |
WV0435 # 04 Y:2011 | 04 | 2011 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,758 | $272 | Implemented |
WV0435 # 05 Y:2011 | 05 | 2011 | OPTIMIZE PLANT POWER FACTOR | $2,651 | $5,480 | Not Implemented |
WV0435 # 06 Y:2011 | 06 | 2011 | DEVELOP A REPAIR/REPLACE POLICY | $1,546 | $668 | Implemented |
WV0435 # 07 Y:2011 | 07 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,437 | $4,415 | Implemented |
WV0435 # 08 Y:2011 | 08 | 2011 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $1,264 | $3,284 | Not Implemented |
WV0435 # 09 Y:2011 | 09 | 2011 | ESTABLISH A PREDICTIVE MAINTENANCE PROGRAM | $1,230 | $1,000 | Implemented |
WV0435 # 10 Y:2011 | 10 | 2011 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $737 | $878 | Not Implemented |
WV0435 # 11 Y:2011 | 11 | 2011 | USE SYNTHETIC LUBRICANT | $608 | $516 | Implemented |
WV0435 # 12 Y:2011 | 12 | 2011 | REMOVE OR CLOSE OFF UNNEEDED COMPRESSED AIR LINES | $330 | $66 | Implemented |
WV0435 # 13 Y:2011 | 13 | 2011 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $190 | $16 | Implemented |
UD0842 # 01 Y:2011 | 01 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $5,006 | $0 | Implemented |
UD0842 # 02 Y:2011 | 02 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,560 | $5,325 | Not Implemented |