Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
3,797
matching recommendationsNAICS | 326199 | All Other Plastics Product Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
IC0143 # 07 Y:2008 | 07 | 2008 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $5,544 | $1,035 | Implemented |
IC0143 # 08 Y:2008 | 08 | 2008 | INSULATE BARE EQUIPMENT | $688 | $580 | Not Implemented |
IC0143 # 09 Y:2008 | 09 | 2008 | REPAIR FURNACES AND OVEN DOORS SO THAT THEY SEAL EFFICIENTLY | $1,040 | $37 | Implemented |
IC0143 # 10 Y:2008 | 10 | 2008 | INSULATE BARE EQUIPMENT | $50 | $42 | Not Implemented |
IC0143 # 11 Y:2008 | 11 | 2008 | REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL | $6,202 | $32,361 | Implemented |
IC0143 # 12 Y:2008 | 12 | 2008 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $541 | $0 | Implemented |
IC0143 # 13 Y:2008 | 13 | 2008 | CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES | $195 | $0 | Not Implemented |
UD0784 # 01 Y:2008 | 01 | 2008 | EMPLOY MODULAR JIGS TO REDUCE PROCESS SET-UP TIME | $123,480 | $15,500 | Not Implemented |
UD0784 # 02 Y:2008 | 02 | 2008 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $46,375 | $75,000 | Not Implemented |
UD0784 # 03 Y:2008 | 03 | 2008 | OPTIMIZE PLANT POWER FACTOR | $44,362 | $13,500 | Not Implemented |
UD0784 # 04 Y:2008 | 04 | 2008 | USE POWER DURING OFF-PEAK PERIODS | $19,834 | $0 | Not Implemented |
UD0784 # 05 Y:2008 | 05 | 2008 | SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY | $19,298 | $4,400 | Not Implemented |
UD0784 # 06 Y:2008 | 06 | 2008 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $15,375 | $24,502 | Not Implemented |
UD0784 # 07 Y:2008 | 07 | 2008 | USE RADIANT HEATER FOR SPOT HEATING | $14,677 | $26,000 | Not Implemented |
UD0784 # 08 Y:2008 | 08 | 2008 | SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY | $10,565 | $24,000 | Not Implemented |
UD0784 # 09 Y:2008 | 09 | 2008 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $9,327 | $17,943 | Not Implemented |
UD0784 # 10 Y:2008 | 10 | 2008 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $7,128 | $0 | Not Implemented |
UD0784 # 11 Y:2008 | 11 | 2008 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $5,237 | $12,500 | Not Implemented |
UD0784 # 12 Y:2008 | 12 | 2008 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $5,465 | $7,440 | Not Implemented |
UD0784 # 13 Y:2008 | 13 | 2008 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $2,512 | $0 | Not Implemented |
UD0784 # 14 Y:2008 | 14 | 2008 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,907 | $0 | Not Implemented |
UD0784 # 15 Y:2008 | 15 | 2008 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,701 | $2,000 | Not Implemented |
UD0784 # 16 Y:2008 | 16 | 2008 | UPGRADE CONTROLS ON COMPRESSORS | $828 | $0 | Not Implemented |
UD0784 # 17 Y:2008 | 17 | 2008 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $980 | $1,000 | Not Implemented |
BD0349 # 01 Y:2008 | 01 | 2008 | INSTALL OCCUPANCY SENSORS | $8,788 | $1,125 | Implemented |