Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

3,797

matching recommendations
Reset
NAICS 326199 All Other Plastics Product Manufacturing
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
UD0719 # 07 Y:2005 07 2005 DISCONNECT BALLASTS $1,102 $75 Implemented
UD0719 # 08 Y:2005 08 2005 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $583 $0 Not Implemented
UD0719 # 09 Y:2005 09 2005 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $583 $20 Implemented
UD0719 # 10 Y:2005 10 2005 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $485 $970 Not Implemented
UD0719 # 11 Y:2005 11 2005 CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE $429 $0 Not Implemented
UD0718 # 01 Y:2005 01 2005 USE FIXTURES TO REDUCE MACHINE CHANGEOUT TIMES $409,000 $15,000 Not Implemented
UD0718 # 02 Y:2005 02 2005 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $77,400 $62,900 Not Implemented
UD0718 # 03 Y:2005 03 2005 USE FIXTURES TO REDUCE MACHINE CHANGEOUT TIMES $64,584 $200,000 Implemented
UD0718 # 04 Y:2005 04 2005 INSULATE BARE EQUIPMENT $42,615 $44,322 Not Implemented
UD0718 # 05 Y:2005 05 2005 DEVELOP A REPAIR/REPLACE POLICY $45,734 $178,576 Not Implemented
UD0718 # 06 Y:2005 06 2005 REDUCE VENTILATION AIR $37,367 $19,721 Not Implemented
UD0718 # 07 Y:2005 07 2005 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $19,025 $13,430 Not Implemented
UD0718 # 08 Y:2005 08 2005 USE PHOTOCELL CONTROLS $4,300 $12,500 Not Implemented
UD0718 # 09 Y:2005 09 2005 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $3,805 $2,598 Not Implemented
UD0718 # 10 Y:2005 10 2005 USE POWER DURING OFF-PEAK PERIODS $2,913 $0 Not Implemented
UD0718 # 11 Y:2005 11 2005 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $1,522 $3,044 Implemented
UD0718 # 12 Y:2005 12 2005 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $762 $362 Not Implemented
LM0097 # 01 Y:2005 01 2005 DEVELOP STANDARD OPERATING PROCEDURES $48,120 $4,921 Implemented
LM0097 # 02 Y:2005 02 2005 TRAIN OPERATORS FOR MAXIMUM OPERATING EFFICIENCY $10,000 $6,000 Not Implemented
LM0097 # 03 Y:2005 03 2005 TRAIN OPERATORS FOR MAXIMUM OPERATING EFFICIENCY $166,760 $6,090 Not Implemented
LM0097 # 04 Y:2005 04 2005 RE-ARRANGE EQUIPMENT LAYOUT TO REDUCE LABOR COSTS $53,375 $1,500 Implemented
LM0097 # 05 Y:2005 05 2005 DEVELOP STANDARD PROCEDURES TO IMPROVE INTERNAL YIELDS $1,250 $0 Implemented
LM0097 # 06 Y:2005 06 2005 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $284 $50 Implemented
LM0097 # 07 Y:2005 07 2005 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $933 $35,082 Implemented
IC0099 # 01 Y:2005 01 2005 USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING $6,719 $35,000 Not Implemented