Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
71
matching recommendationsNAICS | 326199 | All Other Plastics Product Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
NC0663 # 03 Y:2021 | 03 | 2021 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $4,320 | $8,144 | n/a |
NC0663 # 01 Y:2021 | 01 | 2021 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,885 | $3,168 | n/a |
NC0663 # 02 Y:2021 | 02 | 2021 | USE PHOTOCELL CONTROLS | $191 | $300 | n/a |
NC0629 # 02 Y:2019 | 02 | 2019 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,106 | $100 | Not Implemented |
NC0629 # 08 Y:2019 | 08 | 2019 | AVOID REWINDING MOTORS MORE THAN TWICE | $11,808 | $25,282 | Not Implemented |
NC0629 # 07 Y:2019 | 07 | 2019 | RECOVER WASTE HEAT FROM EQUIPMENT | $35,842 | $115,000 | Not Implemented |
NC0629 # 04 Y:2019 | 04 | 2019 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $8,371 | $5,000 | Not Implemented |
NC0629 # 05 Y:2019 | 05 | 2019 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $2,460 | $1,000 | Not Implemented |
NC0629 # 06 Y:2019 | 06 | 2019 | INSTALL / REPAIR INSULATION ON STEAM LINES | $329 | $250 | Not Implemented |
NC0629 # 01 Y:2019 | 01 | 2019 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,243 | $610 | Implemented |
NC0629 # 03 Y:2019 | 03 | 2019 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $281 | $750 | Not Implemented |
NC0620 # 03 Y:2018 | 03 | 2018 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $5,426 | $100 | Implemented |
NC0620 # 05 Y:2018 | 05 | 2018 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $927 | $1,000 | Implemented |
NC0620 # 06 Y:2018 | 06 | 2018 | RECOVER WASTE HEAT FROM EQUIPMENT | $45,926 | $200,000 | Not Implemented |
NC0620 # 04 Y:2018 | 04 | 2018 | USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING | $21,184 | $100,000 | Not Implemented |
NC0620 # 01 Y:2018 | 01 | 2018 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $1,189 | $2,250 | Implemented |
NC0620 # 02 Y:2018 | 02 | 2018 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $3,305 | $10,000 | Not Implemented |
NC0615 # 04 Y:2018 | 04 | 2018 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $197 | $900 | Not Implemented |
NC0615 # 03 Y:2018 | 03 | 2018 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,044 | $165 | Implemented |
NC0615 # 06 Y:2018 | 06 | 2018 | UPGRADE CONTROLS ON COMPRESSORS | $1,380 | $4,000 | Not Implemented |
NC0615 # 09 Y:2018 | 09 | 2018 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $17,615 | $500 | Not Implemented |
NC0615 # 01 Y:2018 | 01 | 2018 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $13,150 | $25,474 | Implemented |
NC0615 # 02 Y:2018 | 02 | 2018 | INSTALL OCCUPANCY SENSORS | $250 | $250 | Not Implemented |
NC0615 # 05 Y:2018 | 05 | 2018 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $206 | $50 | Not Implemented |
NC0615 # 08 Y:2018 | 08 | 2018 | SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY | $6,491 | $3,500 | Not Implemented |