Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
53
matching recommendationsNAICS | 3262 | Rubber Product Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
MZ0084 # 06 Y:2012 | 06 | 2012 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $7,736 | $11,730 | Implemented |
MZ0084 # 02 Y:2012 | 02 | 2012 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,756 | $3,500 | Implemented |
MZ0084 # 01 Y:2012 | 01 | 2012 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $5,602 | $15,200 | Implemented |
MZ0084 # 05 Y:2012 | 05 | 2012 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $12,831 | $37,520 | Not Implemented |
MZ0084 # 07 Y:2012 | 07 | 2012 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $1,142 | $1,000 | Not Implemented |
MZ0084 # 08 Y:2012 | 08 | 2012 | ELIMINATE/REDUCE AN OPERATION | $6,939 | $0 | Implemented |
MZ0084 # 09 Y:2012 | 09 | 2012 | INSULATE BARE EQUIPMENT | $1,483 | $2,500 | Implemented |
MZ0084 # 10 Y:2012 | 10 | 2012 | OPERATE BOILERS ON HIGH FIRE SETTING | $10,918 | $1,770 | Implemented |
MZ0084 # 04 Y:2012 | 04 | 2012 | UTILIZE OUTSIDE AIR INSTEAD OF CONDITIONED AIR FOR DRYING | $1,897 | $2,400 | Not Implemented |
MZ0084 # 03 Y:2012 | 03 | 2012 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $2,987 | $500 | Not Implemented |
MZ0036 # 02 Y:2009 | 02 | 2009 | RECOVER WASTE HEAT FROM EQUIPMENT | $22,645 | $1,500 | Not Implemented |
MZ0036 # 05 Y:2009 | 05 | 2009 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $62,000 | $850 | Implemented |
MZ0036 # 04 Y:2009 | 04 | 2009 | INSTALL DIRECT ACTING UNITS IN PLACE OF COMPRESSED AIR PRESSURE SYSTEM IN SAFETY SYSTEM | $4,395 | $8,757 | Implemented |
MZ0036 # 03 Y:2009 | 03 | 2009 | INSTALL DIRECT ACTING UNITS IN PLACE OF COMPRESSED AIR PRESSURE SYSTEM IN SAFETY SYSTEM | $2,267 | $5,320 | Not Implemented |
MZ0036 # 01 Y:2009 | 01 | 2009 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $32,757 | $26,855 | Implemented |
MZ0034 # 04 Y:2009 | 04 | 2009 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $25,188 | $32,000 | Implemented |
MZ0034 # 03 Y:2009 | 03 | 2009 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $3,996 | $0 | Implemented |
MZ0034 # 02 Y:2009 | 02 | 2009 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $625 | $650 | Implemented |
MZ0034 # 01 Y:2009 | 01 | 2009 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $14,217 | $1,000 | Implemented |
MZ0034 # 05 Y:2009 | 05 | 2009 | INSTALL OCCUPANCY SENSORS | $5,200 | $532 | Implemented |
MZ0034 # 06 Y:2009 | 06 | 2009 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $39,780 | $3,000 | Not Implemented |
MZ0034 # 07 Y:2009 | 07 | 2009 | USE SMALL NUMBER OF HIGH OUTPUT UNITS INSTEAD OF MANY SMALL INEFFICIENT UNITS | $13,376 | $20,000 | Implemented |
MZ0033 # 04 Y:2009 | 04 | 2009 | INSTALL OCCUPANCY SENSORS | $259 | $178 | Implemented |
MZ0033 # 03 Y:2009 | 03 | 2009 | INSTALL OCCUPANCY SENSORS | $169 | $178 | Implemented |
MZ0033 # 02 Y:2009 | 02 | 2009 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $14,040 | $46,900 | Implemented |