Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
152
matching recommendationsNAICS | 32629 | Other Rubber Product Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
MA0561 # 06 Y:2004 | 06 | 2004 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $3,473 | $2,750 | Implemented |
MA0561 # 02 Y:2004 | 02 | 2004 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $30,006 | $25,500 | Implemented |
MA0561 # 04 Y:2004 | 04 | 2004 | REDUCE VENTILATION AIR | $6,815 | $4,530 | Implemented |
MA0561 # 03 Y:2004 | 03 | 2004 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $7,624 | $4,550 | Implemented |
MA0561 # 05 Y:2004 | 05 | 2004 | INSULATE BARE EQUIPMENT | $3,147 | $735 | Implemented |
MA0561 # 01 Y:2004 | 01 | 2004 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $31,924 | $75,720 | Implemented |
BD0268 # 12 Y:2004 | 12 | 2004 | USE LESS WASTEFUL PACKAGING | $1,586 | $3,600 | Implemented |
BD0268 # 01 Y:2004 | 01 | 2004 | AIR CONDITION ONLY SPACE NECESSARY | $352,557 | $1,500,000 | Implemented |
BD0268 # 13 Y:2004 | 13 | 2004 | TRAIN OPERATORS FOR MAXIMUM OPERATING EFFICIENCY | $861 | $173 | Implemented |
BD0268 # 11 Y:2004 | 11 | 2004 | CHANGE PROCEDURES / EQUIPMENT / OPERATING CONDITIONS | $15,653 | $6,914 | Implemented |
BD0268 # 10 Y:2004 | 10 | 2004 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $461 | $20 | Implemented |
BD0268 # 09 Y:2004 | 09 | 2004 | USE PHOTOCELL CONTROLS | $605 | $240 | Not Implemented |
BD0268 # 08 Y:2004 | 08 | 2004 | INSTALL OCCUPANCY SENSORS | $784 | $1,320 | Not Implemented |
BD0268 # 07 Y:2004 | 07 | 2004 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $2,701 | $1,500 | Implemented |
BD0268 # 06 Y:2004 | 06 | 2004 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $5,170 | $200 | Implemented |
BD0268 # 05 Y:2004 | 05 | 2004 | ADD AREA LIGHTING SWITCHES | $14,266 | $9,000 | Not Implemented |
BD0268 # 04 Y:2004 | 04 | 2004 | HEAT WATER WITH EXHAUST HEAT | $31,790 | $35,000 | Implemented |
BD0268 # 03 Y:2004 | 03 | 2004 | ADJUST BURNERS FOR EFFICIENT OPERATION | $40,434 | $49,000 | Implemented |
BD0268 # 02 Y:2004 | 02 | 2004 | SUBSTITUTE HOT PROCESS FLUIDS FOR STEAM | $81,415 | $130,000 | Implemented |
WV0299 # 02 Y:2004 | 02 | 2004 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $9,651 | $16,100 | Implemented |
WV0299 # 01 Y:2004 | 01 | 2004 | INSULATE BARE EQUIPMENT | $10,724 | $2,060 | Implemented |
WV0299 # 05 Y:2004 | 05 | 2004 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $3,704 | $2,175 | Not Implemented |
WV0299 # 06 Y:2004 | 06 | 2004 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $2,363 | $300 | Implemented |
WV0299 # 04 Y:2004 | 04 | 2004 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $4,783 | $1,937 | Implemented |
WV0299 # 03 Y:2004 | 03 | 2004 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $5,725 | $1,000 | Implemented |