Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
150
matching recommendationsNAICS | 327 | Nonmetallic Mineral Product Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
SU0463 # 04 Y:2018 | 04 | 2018 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,966 | $4,800 | Implemented |
SU0463 # 05 Y:2018 | 05 | 2018 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $3,314 | $8,600 | Not Implemented |
SU0463 # 06 Y:2018 | 06 | 2018 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $3,345 | $14,020 | Not Implemented |
SU0431 # 01 Y:2016 | 01 | 2016 | DISCONNECT BALLASTS | $270 | $0 | Implemented |
SU0431 # 02 Y:2016 | 02 | 2016 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $2,312 | $0 | Implemented |
SU0431 # 03 Y:2016 | 03 | 2016 | INSULATE FEEDWATER TANK | $162 | $56 | Implemented |
SU0431 # 04 Y:2016 | 04 | 2016 | ELIMINATE/REDUCE AN OPERATION | $10,608 | $4,074 | Not Implemented |
SU0431 # 05 Y:2016 | 05 | 2016 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $391 | $388 | Not Implemented |
SU0431 # 06 Y:2016 | 06 | 2016 | CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES | $428 | $991 | Implemented |
SU0431 # 07 Y:2016 | 07 | 2016 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $132 | $393 | Implemented |
SU0431 # 08 Y:2016 | 08 | 2016 | INSTALL OCCUPANCY SENSORS | $757 | $3,080 | Implemented |
SU0311 # 01 Y:2011 | 01 | 2011 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $379 | $0 | Implemented |
SU0311 # 02 Y:2011 | 02 | 2011 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $12,621 | $1,125 | Implemented |
SU0311 # 03 Y:2011 | 03 | 2011 | INSTALL OCCUPANCY SENSORS | $2,682 | $3,759 | Implemented |
SU0311 # 04 Y:2011 | 04 | 2011 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $7,617 | $15,000 | Not Implemented |
SU0311 # 05 Y:2011 | 05 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $9,276 | $19,890 | Implemented |
SU0311 # 06 Y:2011 | 06 | 2011 | CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES | $111 | $313 | Not Implemented |
SU0311 # 07 Y:2011 | 07 | 2011 | OPTIMIZE PLANT POWER FACTOR | $2,386 | $21,091 | Implemented |
SU0292 # 01 Y:2010 | 01 | 2010 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $22,577 | $0 | Not Implemented |
SU0292 # 02 Y:2010 | 02 | 2010 | REPAIR AND ELIMINATE STEAM LEAKS | $4,309 | $46 | Implemented |
SU0292 # 03 Y:2010 | 03 | 2010 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,292 | $962 | Implemented |
SU0292 # 04 Y:2010 | 04 | 2010 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $5,754 | $5,714 | Not Implemented |
SU0292 # 05 Y:2010 | 05 | 2010 | CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES | $274 | $560 | Not Implemented |
SU0292 # 06 Y:2010 | 06 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $35,377 | $81,156 | Not Implemented |
SU0292 # 07 Y:2010 | 07 | 2010 | RECOVER WASTE HEAT FROM EQUIPMENT | $57,316 | $175,000 | Not Implemented |