Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
78
matching recommendationsNAICS | 327 | Nonmetallic Mineral Product Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
OK0769 # 01 Y:2008 | 01 | 2008 | INSTALL / REPAIR INSULATION ON STEAM LINES | $53,558 | $2,347 | Not Implemented |
OK0769 # 02 Y:2008 | 02 | 2008 | INSTALL / REPAIR INSULATION ON STEAM LINES | $18,368 | $731 | Not Implemented |
OK0769 # 03 Y:2008 | 03 | 2008 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $788 | $1,922 | Implemented |
OK0769 # 04 Y:2008 | 04 | 2008 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $98,641 | $246,228 | Not Implemented |
OK0769 # 05 Y:2008 | 05 | 2008 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $21,911 | $4,475 | Implemented |
OK0769 # 06 Y:2008 | 06 | 2008 | BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE | $2,068 | $200 | Not Implemented |
OK0769 # 07 Y:2008 | 07 | 2008 | USE WASTE HEAT WITH A CLOSED-CYCLE GAS TURBINE-GENERATOR SET TO COGENERATE ELECTRICITY AND HEAT | $451,827 | $2,500,000 | Not Implemented |
OK0717 # 02 Y:2005 | 02 | 2005 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $4,162 | $7,760 | Not Implemented |
OK0717 # 01 Y:2005 | 01 | 2005 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $38,551 | $53,370 | Implemented |
OK0717 # 06 Y:2005 | 06 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,658 | $461 | Not Implemented |
OK0717 # 05 Y:2005 | 05 | 2005 | DEVELOP A REPAIR/REPLACE POLICY | $1,002 | $9,712 | Implemented |
OK0717 # 04 Y:2005 | 04 | 2005 | INSULATE BARE EQUIPMENT | $1,466 | $1,039 | Implemented |
OK0717 # 03 Y:2005 | 03 | 2005 | USE COMPRESSOR AIR FILTERS | $111 | $417 | Not Implemented |
OK0716 # 07 Y:2005 | 07 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $153 | $1,346 | Not Implemented |
OK0716 # 06 Y:2005 | 06 | 2005 | INSTALL TIMERS AND/OR THERMOSTATS | $579 | $25 | Not Implemented |
OK0716 # 05 Y:2005 | 05 | 2005 | INSTALL OCCUPANCY SENSORS | $212 | $475 | Not Implemented |
OK0716 # 04 Y:2005 | 04 | 2005 | USE PHOTOCELL CONTROLS | $1,725 | $125 | Not Implemented |
OK0716 # 03 Y:2005 | 03 | 2005 | ADD EQUIPMENT/ OPERATORS TO REDUCE PRODUCTION BOTTLENECK | $-28,676 | $0 | Not Implemented |
OK0716 # 02 Y:2005 | 02 | 2005 | BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE | $1,900 | $200 | Not Implemented |
OK0716 # 01 Y:2005 | 01 | 2005 | OPTIMIZE PLANT POWER FACTOR | $10,863 | $38,544 | Not Implemented |
OK0711 # 01 Y:2005 | 01 | 2005 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $10,068 | $25,248 | Not Implemented |
OK0711 # 02 Y:2005 | 02 | 2005 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $333 | $647 | Not Implemented |
OK0711 # 03 Y:2005 | 03 | 2005 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,907 | $3,150 | Not Implemented |
OK0711 # 04 Y:2005 | 04 | 2005 | CHILL WATER TO THE HIGHEST TEMPERATURE POSSIBLE | $13,929 | $125 | Not Implemented |
OK0711 # 05 Y:2005 | 05 | 2005 | BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE | $8,800 | $0 | Not Implemented |