IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

187

matching recommendations
Reset
NAICS 327 Nonmetallic Mineral Product Manufacturing
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
SD0351 # 01 Y:2004 01 2004 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $217,864 $75,000 Not Implemented
SD0351 # 02 Y:2004 02 2004 USE A FOSSIL FUEL ENGINE TO COGENERATE ELECTRICITY OR MOTIVE POWER; AND UTILIZE HEAT $80,766 $255,442 Implemented
SD0351 # 03 Y:2004 03 2004 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $34,754 $39,050 Implemented
SD0351 # 04 Y:2004 04 2004 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $7,248 $14,785 Implemented
SD0351 # 05 Y:2004 05 2004 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $2,257 $350 Implemented
SD0351 # 06 Y:2004 06 2004 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $663 $0 Implemented
SD0351 # 07 Y:2004 07 2004 PAY UTILITY BILLS ON TIME $1,391 $0 Implemented
LM0077 # 01 Y:2004 01 2004 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $1,750 $3,825 Not Implemented
LM0077 # 02 Y:2004 02 2004 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $117 $0 Implemented
LM0077 # 03 Y:2004 03 2004 DO NOT USE COMPRESSED AIR FOR PERSONAL COOLING $91 $100 Implemented
LM0077 # 04 Y:2004 04 2004 TRAIN OPERATORS FOR MAXIMUM OPERATING EFFICIENCY $36,400 $8,800 Not Implemented
LM0077 # 05 Y:2004 05 2004 RE-ARRANGE EQUIPMENT LAYOUT TO REDUCE LABOR COSTS $812 $0 Implemented
LM0077 # 06 Y:2004 06 2004 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $997 $1,920 Not Implemented
SF0281 # 01 Y:2004 01 2004 USE / PURCHASE OPTIMUM SIZED COMPRESSOR $1,183 $233 Not Implemented
SF0281 # 02 Y:2004 02 2004 USE PHOTOCELL CONTROLS $1,246 $1,800 Not Implemented
SF0281 # 03 Y:2004 03 2004 USE INSULATION IN FURNACES TO FACILITATE HEATING / COOLING $2,651 $4,263 Not Implemented
SF0281 # 04 Y:2004 04 2004 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $2,270 $5,700 Not Implemented
SF0281 # 05 Y:2004 05 2004 INSTALL SKYLIGHTS $219 $640 Not Implemented
SF0281 # 06 Y:2004 06 2004 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $940 $3,016 Not Implemented
SF0277 # 01 Y:2004 01 2004 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME $38,710 $0 Implemented
SF0277 # 02 Y:2004 02 2004 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $9,221 $0 Implemented
SF0277 # 03 Y:2004 03 2004 TURN OFF EQUIPMENT WHEN NOT IN USE $2,460 $720 Implemented
SF0277 # 04 Y:2004 04 2004 TURN OFF EQUIPMENT WHEN NOT IN USE $954 $240 Not Implemented
SF0277 # 05 Y:2004 05 2004 TURN OFF EQUIPMENT WHEN NOT IN USE $784 $240 Implemented
SF0277 # 06 Y:2004 06 2004 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $16,226 $5,882 Not Implemented