Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
167
matching recommendationsNAICS | 327 | Nonmetallic Mineral Product Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
WV0348 # 15 Y:2006 | 15 | 2006 | DEVELOP A REPAIR/REPLACE POLICY | $866 | $680 | Implemented |
WV0348 # 16 Y:2006 | 16 | 2006 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $545 | $266 | Implemented |
WV0348 # 17 Y:2006 | 17 | 2006 | RECOVER WASTE HEAT FROM EQUIPMENT | $528 | $880 | Not Implemented |
WV0306 # 01 Y:2004 | 01 | 2004 | PREHEAT COMBUSTION AIR WITH WASTE HEAT | $30,489 | $20,910 | Not Implemented |
WV0306 # 02 Y:2004 | 02 | 2004 | INSULATE BARE EQUIPMENT | $17,374 | $5,922 | Implemented |
WV0306 # 03 Y:2004 | 03 | 2004 | RECOVER WASTE HEAT FROM EQUIPMENT | $2,768 | $660 | Not Implemented |
WV0306 # 04 Y:2004 | 04 | 2004 | RECYCLE AIR FOR HEATING, VENTILATION AND AIR CONDITIONING | $2,517 | $370 | Not Implemented |
WV0306 # 05 Y:2004 | 05 | 2004 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,967 | $2,040 | Implemented |
WV0306 # 06 Y:2004 | 06 | 2004 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,591 | $420 | Not Implemented |
WV0306 # 07 Y:2004 | 07 | 2004 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $1,120 | $520 | Not Implemented |
WV0306 # 08 Y:2004 | 08 | 2004 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $985 | $160 | Implemented |
WV0306 # 09 Y:2004 | 09 | 2004 | DEVELOP A REPAIR/REPLACE POLICY | $934 | $160 | Implemented |
WV0306 # 10 Y:2004 | 10 | 2004 | ESTABLISH EQUIPMENT MAINTENANCE SCHEDULE | $796 | $40 | Implemented |
WV0306 # 11 Y:2004 | 11 | 2004 | USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING | $777 | $1,060 | Not Implemented |
WV0306 # 12 Y:2004 | 12 | 2004 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $696 | $3,480 | Implemented |
WV0306 # 13 Y:2004 | 13 | 2004 | INSTALL OCCUPANCY SENSORS | $395 | $800 | Implemented |
WV0306 # 14 Y:2004 | 14 | 2004 | UTILIZE A LESS EXPENSIVE COOLING METHOD | $318 | $105 | Not Implemented |