Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
406
matching recommendationsNAICS | 32712 | Clay Building Material and Refractories Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
TT0087 # 03 Y:2012 | 03 | 2012 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $12,922 | $3,000 | Not Implemented |
TT0087 # 04 Y:2012 | 04 | 2012 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $7,063 | $3,000 | Not Implemented |
TT0087 # 05 Y:2012 | 05 | 2012 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $9,302 | $30,000 | Implemented |
TT0087 # 06 Y:2012 | 06 | 2012 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $24,772 | $20 | Implemented |
TT0087 # 07 Y:2012 | 07 | 2012 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $356,049 | $220,018 | Implemented |
TT0087 # 08 Y:2012 | 08 | 2012 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $494 | $5,940 | Implemented |
TT0087 # 09 Y:2012 | 09 | 2012 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $538 | $858 | Implemented |
TT0087 # 10 Y:2012 | 10 | 2012 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $700 | $5,850 | Implemented |
TT0087 # 11 Y:2012 | 11 | 2012 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $7,312 | $20,358 | Not Implemented |
TT0087 # 12 Y:2012 | 12 | 2012 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $693 | $1,225 | Not Implemented |
TT0087 # 13 Y:2012 | 13 | 2012 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $134,178 | $87,250 | Implemented |
TT0087 # 14 Y:2012 | 14 | 2012 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,937 | $23,284 | Implemented |
TT0087 # 15 Y:2012 | 15 | 2012 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $6,403 | $10,218 | Implemented |
TT0087 # 16 Y:2012 | 16 | 2012 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $858 | $7,176 | Implemented |
TT0087 # 17 Y:2012 | 17 | 2012 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,120 | $3,120 | Not Implemented |
TT0087 # 18 Y:2012 | 18 | 2012 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $342 | $595 | Not Implemented |
SU0311 # 01 Y:2011 | 01 | 2011 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $379 | $0 | Implemented |
SU0311 # 02 Y:2011 | 02 | 2011 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $12,621 | $1,125 | Implemented |
SU0311 # 03 Y:2011 | 03 | 2011 | INSTALL OCCUPANCY SENSORS | $2,682 | $3,759 | Implemented |
SU0311 # 04 Y:2011 | 04 | 2011 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $7,617 | $15,000 | Not Implemented |
SU0311 # 05 Y:2011 | 05 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $9,276 | $19,890 | Implemented |
SU0311 # 06 Y:2011 | 06 | 2011 | CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES | $111 | $313 | Not Implemented |
SU0311 # 07 Y:2011 | 07 | 2011 | OPTIMIZE PLANT POWER FACTOR | $2,386 | $21,091 | Implemented |
GT0878 # 01 Y:2011 | 01 | 2011 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $21,600 | $8,000 | Implemented |
GT0878 # 02 Y:2011 | 02 | 2011 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $77,000 | $12,000 | Not Implemented |