IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

51

matching recommendations
Reset
NAICS 3272 Glass and Glass Product Manufacturing
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
CO0558 # 02 Y:2004 02 2004 USE / PURCHASE OPTIMUM SIZED COMPRESSOR $1,700 $2,720 Implemented
CO0558 # 01 Y:2004 01 2004 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $1,990 $350 Implemented
CO0558 # 03 Y:2004 03 2004 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $1,020 $6,030 Implemented
CO0558 # 04 Y:2004 04 2004 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $234 $588 Implemented
CO0558 # 05 Y:2004 05 2004 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS $2,810 $1,910 Not Implemented
CO0558 # 06 Y:2004 06 2004 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,660 $7,410 Implemented
OK0693 # 04 Y:2004 04 2004 USE COOLING TOWER WATER INSTEAD OF REFRIGERATION $2,179 $3,635 Not Implemented
OK0693 # 09 Y:2004 09 2004 INSTALL OCCUPANCY SENSORS $356 $737 Implemented
OK0693 # 08 Y:2004 08 2004 INSTALL TIMERS AND/OR THERMOSTATS $772 $1,140 Implemented
OK0693 # 07 Y:2004 07 2004 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $992 $1,025 Not Implemented
OK0693 # 06 Y:2004 06 2004 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $808 $123 Not Implemented
OK0693 # 05 Y:2004 05 2004 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $5,903 $31,913 Implemented
OK0693 # 03 Y:2004 03 2004 OPTIMIZE PLANT POWER FACTOR $7,010 $10,720 n/a
OK0693 # 02 Y:2004 02 2004 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $28,651 $88,297 Not Implemented
OK0693 # 01 Y:2004 01 2004 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $585,281 $30,200 Not Implemented
MI0088 # 02 Y:2004 02 2004 TURN OFF EQUIPMENT WHEN NOT IN USE $28,772 $2,300 Implemented
MI0088 # 01 Y:2004 01 2004 CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE $2,029 $0 Not Implemented
MI0088 # 06 Y:2004 06 2004 REGRIND, REUSE, OR SELL SCRAP PLASTIC PARTS $17,529 $0 Not Implemented
MI0088 # 03 Y:2004 03 2004 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $-1,117 $750 Implemented
MI0088 # 05 Y:2004 05 2004 ADD EQUIPMENT/ OPERATORS TO REDUCE PRODUCTION BOTTLENECK $427,935 $0 Implemented
MI0088 # 07 Y:2004 07 2004 USE CLOSED CYCLE PROCESS TO MINIMIZE WASTE WATER PRODUCTION $14,310 $0 Not Implemented
MI0088 # 08 Y:2004 08 2004 PAY BILLS ON TIME TO AVOID LATE FEES $770 $0 Implemented
MI0088 # 04 Y:2004 04 2004 USE / PURCHASE OPTIMUM SIZED COMPRESSOR $22,760 $40,140 Implemented
LM0077 # 03 Y:2004 03 2004 DO NOT USE COMPRESSED AIR FOR PERSONAL COOLING $91 $100 Implemented
LM0077 # 05 Y:2004 05 2004 RE-ARRANGE EQUIPMENT LAYOUT TO REDUCE LABOR COSTS $812 $0 Implemented