IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

20

matching recommendations
Reset
NAICS 327910 Abrasive Product Manufacturing
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
UF0438 # 03 Y:2010 03 2010 AIR CONDITION ONLY SPACE NECESSARY $15,093 $1,615 Not Implemented
UF0438 # 12 Y:2010 12 2010 PREHEAT COMBUSTION AIR WITH WASTE HEAT $8,717 $0 Not Implemented
UF0438 # 11 Y:2010 11 2010 REPAIR OR REPLACE STEAM TRAPS $14,482 $0 Not Implemented
UF0438 # 10 Y:2010 10 2010 PREHEAT COMBUSTION AIR WITH WASTE HEAT $14,054 $0 Not Implemented
UF0438 # 09 Y:2010 09 2010 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $59,220 $44,118 Not Implemented
UF0438 # 08 Y:2010 08 2010 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $1,272 $2,160 Not Implemented
UF0438 # 07 Y:2010 07 2010 TURN OFF EQUIPMENT WHEN NOT IN USE $6,023 $3,670 Not Implemented
UF0438 # 06 Y:2010 06 2010 UPGRADE CONTROLS ON COMPRESSORS $24,615 $975 Not Implemented
UF0438 # 05 Y:2010 05 2010 USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE $112,650 $154,062 Not Implemented
UF0438 # 04 Y:2010 04 2010 AIR CONDITION ONLY SPACE NECESSARY $10,754 $22,000 Not Implemented
UF0438 # 02 Y:2010 02 2010 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $85,202 $72,075 Not Implemented
UF0438 # 01 Y:2010 01 2010 INSTALL OCCUPANCY SENSORS $22,343 $1,105 Not Implemented
UD0762 # 01 Y:2007 01 2007 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $25,211 $0 Implemented
UD0762 # 08 Y:2007 08 2007 DISCONNECT BALLASTS $1,029 $180 Not Implemented
UD0762 # 07 Y:2007 07 2007 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $1,709 $1,465 Implemented
UD0762 # 06 Y:2007 06 2007 RECOVER WASTE HEAT FROM EQUIPMENT $5,706 $7,000 Not Implemented
UD0762 # 05 Y:2007 05 2007 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $6,048 $19,730 Not Implemented
UD0762 # 04 Y:2007 04 2007 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $6,650 $33,580 Implemented
UD0762 # 03 Y:2007 03 2007 INSULATE BARE EQUIPMENT $22,493 $9,310 Not Implemented
UD0762 # 02 Y:2007 02 2007 USE PLANT OWNED TRANSFORMERS OR LEASE TRANSFORMERS $23,789 $95,156 Not Implemented