Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
342
matching recommendationsNAICS | 32799 | All Other Nonmetallic Mineral Product Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
AS0429 # 03 Y:2006 | 03 | 2006 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,127 | $1,000 | n/a |
AS0429 # 04 Y:2006 | 04 | 2006 | USE OPTIMUM SIZE AND CAPACITY EQUIPMENT | $34 | $3,200 | n/a |
OK0716 # 01 Y:2005 | 01 | 2005 | OPTIMIZE PLANT POWER FACTOR | $10,863 | $38,544 | Not Implemented |
OK0716 # 02 Y:2005 | 02 | 2005 | BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE | $1,900 | $200 | Not Implemented |
OK0716 # 03 Y:2005 | 03 | 2005 | ADD EQUIPMENT/ OPERATORS TO REDUCE PRODUCTION BOTTLENECK | $-28,676 | $0 | Not Implemented |
OK0716 # 04 Y:2005 | 04 | 2005 | USE PHOTOCELL CONTROLS | $1,725 | $125 | Not Implemented |
OK0716 # 05 Y:2005 | 05 | 2005 | INSTALL OCCUPANCY SENSORS | $212 | $475 | Not Implemented |
OK0716 # 06 Y:2005 | 06 | 2005 | INSTALL TIMERS AND/OR THERMOSTATS | $579 | $25 | Not Implemented |
OK0716 # 07 Y:2005 | 07 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $153 | $1,346 | Not Implemented |
WI0483 # 01 Y:2005 | 01 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $10,449 | $18,810 | n/a |
WI0483 # 02 Y:2005 | 02 | 2005 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $7,950 | $10,000 | Not Implemented |
WI0483 # 03 Y:2005 | 03 | 2005 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $3,804 | $500 | Not Implemented |
WI0483 # 04 Y:2005 | 04 | 2005 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $6,164 | $830 | Implemented |
WI0483 # 05 Y:2005 | 05 | 2005 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $2,971 | $2,186 | Not Implemented |
WI0483 # 06 Y:2005 | 06 | 2005 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,886 | $0 | Not Implemented |
WI0483 # 07 Y:2005 | 07 | 2005 | INSULATE BARE EQUIPMENT | $393 | $40 | Not Implemented |
WV0306 # 01 Y:2004 | 01 | 2004 | PREHEAT COMBUSTION AIR WITH WASTE HEAT | $30,489 | $20,910 | Not Implemented |
WV0306 # 02 Y:2004 | 02 | 2004 | INSULATE BARE EQUIPMENT | $17,374 | $5,922 | Implemented |
WV0306 # 03 Y:2004 | 03 | 2004 | RECOVER WASTE HEAT FROM EQUIPMENT | $2,768 | $660 | Not Implemented |
WV0306 # 04 Y:2004 | 04 | 2004 | RECYCLE AIR FOR HEATING, VENTILATION AND AIR CONDITIONING | $2,517 | $370 | Not Implemented |
WV0306 # 05 Y:2004 | 05 | 2004 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,967 | $2,040 | Implemented |
WV0306 # 06 Y:2004 | 06 | 2004 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,591 | $420 | Not Implemented |
WV0306 # 07 Y:2004 | 07 | 2004 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $1,120 | $520 | Not Implemented |
WV0306 # 08 Y:2004 | 08 | 2004 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $985 | $160 | Implemented |
WV0306 # 09 Y:2004 | 09 | 2004 | DEVELOP A REPAIR/REPLACE POLICY | $934 | $160 | Implemented |