Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

23

matching recommendations
Reset
NAICS 327993 Mineral Wool Manufacturing
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
UD0925 # 02 Y:2015 02 2015 INSULATE BARE EQUIPMENT $221,454 $15,345 Not Implemented
UD0925 # 03 Y:2015 03 2015 USE OPTIMUM TEMPERATURE $46,665 $0 Not Implemented
UD0925 # 04 Y:2015 04 2015 UPGRADE CONTROLS ON COMPRESSORS $4,804 $34,000 Not Implemented
UD0925 # 05 Y:2015 05 2015 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $3,759 $5,000 Not Implemented
UD0925 # 06 Y:2015 06 2015 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $2,964 $1,000 Implemented
UD0925 # 07 Y:2015 07 2015 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $15,405 $66,200 Not Implemented
UD0925 # 08 Y:2015 08 2015 INSTALL SENSORS TO DETECT AND AVOID JAMS $7,714 $120,000 Implemented
UD0925 # 09 Y:2015 09 2015 CONTRACT A WOOD PALLET RECYCLING COMPANY $5,400 $0 Not Implemented
UD0925 # 01 Y:2015 01 2015 CHILL WATER TO THE HIGHEST TEMPERATURE POSSIBLE $860 $0 Implemented
WV0306 # 14 Y:2004 14 2004 UTILIZE A LESS EXPENSIVE COOLING METHOD $318 $105 Not Implemented
WV0306 # 13 Y:2004 13 2004 INSTALL OCCUPANCY SENSORS $395 $800 Implemented
WV0306 # 12 Y:2004 12 2004 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $696 $3,480 Implemented
WV0306 # 11 Y:2004 11 2004 USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING $777 $1,060 Not Implemented
WV0306 # 10 Y:2004 10 2004 ESTABLISH EQUIPMENT MAINTENANCE SCHEDULE $796 $40 Implemented
WV0306 # 09 Y:2004 09 2004 DEVELOP A REPAIR/REPLACE POLICY $934 $160 Implemented
WV0306 # 08 Y:2004 08 2004 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $985 $160 Implemented
WV0306 # 07 Y:2004 07 2004 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES $1,120 $520 Not Implemented
WV0306 # 06 Y:2004 06 2004 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $1,591 $420 Not Implemented
WV0306 # 05 Y:2004 05 2004 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $1,967 $2,040 Implemented
WV0306 # 04 Y:2004 04 2004 RECYCLE AIR FOR HEATING, VENTILATION AND AIR CONDITIONING $2,517 $370 Not Implemented
WV0306 # 03 Y:2004 03 2004 RECOVER WASTE HEAT FROM EQUIPMENT $2,768 $660 Not Implemented
WV0306 # 02 Y:2004 02 2004 INSULATE BARE EQUIPMENT $17,374 $5,922 Implemented
WV0306 # 01 Y:2004 01 2004 PREHEAT COMBUSTION AIR WITH WASTE HEAT $30,489 $20,910 Not Implemented