Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
354
matching recommendationsNAICS | 331 | Primary Metal Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
SU0242 # 09 Y:2006 | 09 | 2006 | CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES | $126 | $632 | Implemented |
SU0242 # 10 Y:2006 | 10 | 2006 | INSTALL OCCUPANCY SENSORS | $67 | $432 | Not Implemented |
WV0347 # 06 Y:2006 | 06 | 2006 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $6,834 | $250 | Not Implemented |
WV0347 # 01 Y:2006 | 01 | 2006 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $255,013 | $57,159 | Implemented |
WV0347 # 02 Y:2006 | 02 | 2006 | USE WASTE HEAT FROM FLUE GASES TO HEAT SPACE CONDITIONING AIR | $32,512 | $24,300 | Not Implemented |
WV0347 # 03 Y:2006 | 03 | 2006 | ESTABLISH A PREDICTIVE MAINTENANCE PROGRAM | $11,796 | $1,000 | Implemented |
WV0347 # 11 Y:2006 | 11 | 2006 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $457 | $158 | Not Implemented |
WV0347 # 05 Y:2006 | 05 | 2006 | UTILIZE A LESS EXPENSIVE COOLING METHOD | $10,012 | $13,815 | Not Implemented |
WV0347 # 07 Y:2006 | 07 | 2006 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $5,696 | $10,600 | Not Implemented |
WV0347 # 08 Y:2006 | 08 | 2006 | USE RADIANT HEATER FOR SPOT HEATING | $5,557 | $2,790 | Implemented |
WV0347 # 04 Y:2006 | 04 | 2006 | DEVELOP A REPAIR/REPLACE POLICY | $10,908 | $504 | Implemented |
WV0347 # 10 Y:2006 | 10 | 2006 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $915 | $245 | Not Implemented |
WV0347 # 09 Y:2006 | 09 | 2006 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,051 | $65 | Implemented |
LE0235 # 01 Y:2006 | 01 | 2006 | CONSIDER USE / PURCHASE OF BULK MATERIALS WHERE POSSIBLE | $1,380,000 | $3,000,000 | Not Implemented |
LE0235 # 02 Y:2006 | 02 | 2006 | PREHEAT COMBUSTION AIR WITH WASTE HEAT | $202,503 | $95,000 | Implemented |
LE0235 # 03 Y:2006 | 03 | 2006 | UPGRADE OBSOLETE EQUIPMENT | $192,971 | $250,000 | Implemented |
LE0235 # 04 Y:2006 | 04 | 2006 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $73,559 | $36,000 | Not Implemented |
LE0235 # 05 Y:2006 | 05 | 2006 | ADJUST BURNERS FOR EFFICIENT OPERATION | $66,844 | $100 | Implemented |
LE0235 # 06 Y:2006 | 06 | 2006 | ADJUST BURNERS FOR EFFICIENT OPERATION | $63,349 | $20,000 | Implemented |
LE0235 # 07 Y:2006 | 07 | 2006 | REPAIR FAULTY INSULATION IN FURNACES, BOILERS, ETC | $22,786 | $30,000 | Implemented |
LE0235 # 08 Y:2006 | 08 | 2006 | REDESIGN PROCESS | $19,713 | $1,000 | Not Implemented |
LE0235 # 09 Y:2006 | 09 | 2006 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $12,444 | $6,000 | Implemented |
LE0235 # 10 Y:2006 | 10 | 2006 | PREHEAT COMBUSTION AIR WITH WASTE HEAT | $11,211 | $15,000 | Not Implemented |
LE0235 # 11 Y:2006 | 11 | 2006 | REPAIR FAULTY INSULATION IN FURNACES, BOILERS, ETC | $9,908 | $7,500 | Implemented |
LE0235 # 12 Y:2006 | 12 | 2006 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $6,006 | $1,000 | Implemented |