IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

237

matching recommendations
Reset
NAICS 331 Primary Metal Manufacturing
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
UD0817 # 15 Y:2010 15 2010 INSULATE BARE EQUIPMENT $3,996 $0 Implemented
UD0817 # 16 Y:2010 16 2010 REDESIGN PROCESS $357,330 $0 Not Implemented
UD0817 # 17 Y:2010 17 2010 USE RADIANT HEATER FOR SPOT HEATING $18,312 $36,624 Not Implemented
UD0817 # 18 Y:2010 18 2010 INSTALL / REPAIR INSULATION ON STEAM LINES $1,624 $5,686 Not Implemented
IC0159 # 01 Y:2009 01 2009 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $6,803 $27,853 Not Implemented
IC0159 # 02 Y:2009 02 2009 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $443 $162 Not Implemented
IC0159 # 03 Y:2009 03 2009 INSTALL OCCUPANCY SENSORS $1,629 $1,927 Not Implemented
IC0159 # 04 Y:2009 04 2009 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $171 $238 Not Implemented
IC0159 # 05 Y:2009 05 2009 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,906 $0 Not Implemented
IC0159 # 06 Y:2009 06 2009 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $1,212 $5,316 Not Implemented
IC0159 # 07 Y:2009 07 2009 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $157 $0 Not Implemented
IC0159 # 08 Y:2009 08 2009 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $322 $575 Not Implemented
IC0159 # 09 Y:2009 09 2009 USE OPTIMUM SIZE AND CAPACITY EQUIPMENT $780 $5,456 Not Implemented
IC0159 # 10 Y:2009 10 2009 INSTALL / REPAIR INSULATION ON STEAM LINES $14,132 $5,776 Not Implemented
IC0159 # 11 Y:2009 11 2009 REPAIR AND ELIMINATE STEAM LEAKS $2,694 $57 Not Implemented
IC0159 # 12 Y:2009 12 2009 CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES $166 $0 Not Implemented
UD0721 # 01 Y:2005 01 2005 RECOVER MECHANICAL ENERGY $206,969 $413,938 Implemented
UD0721 # 02 Y:2005 02 2005 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $30,010 $86,100 Implemented
UD0721 # 03 Y:2005 03 2005 REPAIR AND ELIMINATE STEAM LEAKS $11,745 $160 Implemented
UD0721 # 04 Y:2005 04 2005 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $11,579 $12,000 Implemented
UD0721 # 05 Y:2005 05 2005 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $5,580 $0 Implemented
UD0721 # 06 Y:2005 06 2005 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $5,040 $11,100 Implemented
UD0721 # 07 Y:2005 07 2005 INSTALL OCCUPANCY SENSORS $2,714 $345 Not Implemented
UD0721 # 08 Y:2005 08 2005 SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY $1,229 $860 Not Implemented
UD0721 # 09 Y:2005 09 2005 INSULATE BARE EQUIPMENT $675 $1,820 Not Implemented