Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
75
matching recommendationsNAICS | 33122 | Rolling and Drawing of Purchased Steel |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
LE0332 # 09 Y:2012 | 09 | 2012 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $3,360 | $6,400 | Not Implemented |
LE0332 # 10 Y:2012 | 10 | 2012 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $706 | $4,580 | Not Implemented |
LE0283 # 24 Y:2009 | 24 | 2009 | INSTALL OCCUPANCY SENSORS | $550 | $600 | Implemented |
LE0283 # 23 Y:2009 | 23 | 2009 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $7,799 | $32,466 | Implemented |
LE0283 # 22 Y:2009 | 22 | 2009 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $312 | $240 | Not Implemented |
LE0283 # 21 Y:2009 | 21 | 2009 | REPAIR FAULTY INSULATION IN FURNACES, BOILERS, ETC | $608 | $565 | Not Implemented |
LE0283 # 19 Y:2009 | 19 | 2009 | SUBSTITUTE HOT PROCESS FLUIDS FOR STEAM | $1,040 | $600 | Not Implemented |
LE0283 # 10 Y:2009 | 10 | 2009 | REPLACE BOILER | $19,000 | $30,000 | Not Implemented |
LE0283 # 01 Y:2009 | 01 | 2009 | REPAIR FURNACES AND OVEN DOORS SO THAT THEY SEAL EFFICIENTLY | $48,061 | $100,000 | Not Implemented |
LE0283 # 02 Y:2009 | 02 | 2009 | REPLACE DC EQUIPMENT WITH AC EQUIPMENT | $46,426 | $38,000 | Implemented |
LE0283 # 03 Y:2009 | 03 | 2009 | RESCHEDULE AND REARRANGE MULTIPLE-SOURCE HEATING SYSTEMS | $38,523 | $560 | Implemented |
LE0283 # 04 Y:2009 | 04 | 2009 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $30,658 | $1,672 | Implemented |
LE0283 # 05 Y:2009 | 05 | 2009 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $28,610 | $12,000 | Not Implemented |
LE0283 # 06 Y:2009 | 06 | 2009 | REPAIR OR REPLACE STEAM TRAPS | $27,445 | $10,500 | Not Implemented |
LE0283 # 07 Y:2009 | 07 | 2009 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $22,225 | $30,000 | Not Implemented |
LE0283 # 08 Y:2009 | 08 | 2009 | PREHEAT COMBUSTION AIR WITH WASTE HEAT | $21,508 | $30,000 | Not Implemented |
LE0283 # 09 Y:2009 | 09 | 2009 | USE RADIANT HEATER FOR SPOT HEATING | $19,446 | $5,000 | Not Implemented |
LE0283 # 11 Y:2009 | 11 | 2009 | PREHEAT COMBUSTION AIR WITH WASTE HEAT | $18,031 | $30,000 | Implemented |
LE0283 # 12 Y:2009 | 12 | 2009 | COVER OPEN TANKS | $9,339 | $10,000 | Implemented |
LE0283 # 13 Y:2009 | 13 | 2009 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $8,598 | $2,400 | Not Implemented |
LE0283 # 14 Y:2009 | 14 | 2009 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $7,947 | $7,000 | Not Implemented |
LE0283 # 15 Y:2009 | 15 | 2009 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $6,465 | $160 | Not Implemented |
LE0283 # 16 Y:2009 | 16 | 2009 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $5,319 | $800 | Not Implemented |
LE0283 # 17 Y:2009 | 17 | 2009 | MINIMIZE USE OF OUTSIDE MAKE-UP AIR FOR VENTILATION EXCEPT WHEN USED FOR ECONOMIZER CYCLE | $2,129 | $600 | Not Implemented |
LE0283 # 18 Y:2009 | 18 | 2009 | INSTALL / REPAIR INSULATION ON STEAM LINES | $1,121 | $1,000 | Not Implemented |