Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

333

matching recommendations
Reset
NAICS 331221 Rolled Steel Shape Manufacturing
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
LE0283 # 20 Y:2009 20 2009 MINIMIZE USE OF OUTSIDE MAKE-UP AIR FOR VENTILATION EXCEPT WHEN USED FOR ECONOMIZER CYCLE $718 $300 Not Implemented
LE0283 # 21 Y:2009 21 2009 REPAIR FAULTY INSULATION IN FURNACES, BOILERS, ETC $608 $565 Not Implemented
LE0283 # 22 Y:2009 22 2009 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $312 $240 Not Implemented
LE0283 # 23 Y:2009 23 2009 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $7,799 $32,466 Implemented
LE0283 # 24 Y:2009 24 2009 INSTALL OCCUPANCY SENSORS $550 $600 Implemented
OR0535 # 01 Y:2008 01 2008 SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY $46,153 $56,500 Not Implemented
OR0535 # 02 Y:2008 02 2008 CLEAN STEAM COILS IN PROCESSING TANKS $6,588 $1,250 Not Implemented
OR0535 # 03 Y:2008 03 2008 UPGRADE CONTROLS ON COMPRESSORS $43,923 $7,200 Not Implemented
OR0535 # 04 Y:2008 04 2008 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $7,829 $47,094 Not Implemented
OR0535 # 05 Y:2008 05 2008 INSTALL OCCUPANCY SENSORS $2,286 $1,850 Not Implemented
MA0635 # 01 Y:2008 01 2008 USE MINIMUM SAFE OVEN VENTILATION $17,227 $51,900 Implemented
MA0635 # 02 Y:2008 02 2008 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $21,508 $40,166 Not Implemented
MA0635 # 03 Y:2008 03 2008 REDUCE VENTILATION AIR $21,303 $8,200 Implemented
MA0635 # 04 Y:2008 04 2008 REPLACE CITY WATER WITH RECYCLED WATER VIA COOLING TOWER $18,922 $4,000 Implemented
MA0635 # 05 Y:2008 05 2008 BURN A LESS EXPENSIVE GRADE OF FUEL $16,990 $27,590 Implemented
MA0635 # 06 Y:2008 06 2008 COVER OPEN TANKS $13,756 $53,000 Implemented
MA0635 # 07 Y:2008 07 2008 INSTALL / REPAIR INSULATION ON STEAM LINES $10,446 $3,288 Implemented
MA0635 # 08 Y:2008 08 2008 INSULATE GLAZING, WALLS, CEILINGS, AND ROOFS $4,508 $12,000 Not Implemented
MA0635 # 09 Y:2008 09 2008 USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING $3,255 $5,700 Not Implemented
MA0635 # 10 Y:2008 10 2008 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $2,859 $1,200 Not Implemented
MA0635 # 11 Y:2008 11 2008 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $1,035 $1,600 Not Implemented
MA0635 # 12 Y:2008 12 2008 USE MINIMUM SAFE OVEN VENTILATION $880 $500 Implemented
BD0315 # 01 Y:2006 01 2006 USE RADIANT HEATER FOR SPOT HEATING $12,408 $12,368 Not Implemented
BD0315 # 02 Y:2006 02 2006 REPOSITION OVEN WALLS TO REDUCE HEATED SPACE $10,595 $900 Not Implemented
BD0315 # 03 Y:2006 03 2006 RECOVER WASTE HEAT FROM EQUIPMENT $13,074 $16,950 Not Implemented