Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
29
matching recommendationsNAICS | 331221 | Rolled Steel Shape Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UD0817 # 04 Y:2010 | 04 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $9,364 | $1,876 | Not Implemented |
UD0817 # 18 Y:2010 | 18 | 2010 | INSTALL / REPAIR INSULATION ON STEAM LINES | $1,624 | $5,686 | Not Implemented |
UD0817 # 17 Y:2010 | 17 | 2010 | USE RADIANT HEATER FOR SPOT HEATING | $18,312 | $36,624 | Not Implemented |
UD0817 # 16 Y:2010 | 16 | 2010 | REDESIGN PROCESS | $357,330 | $0 | Not Implemented |
UD0817 # 15 Y:2010 | 15 | 2010 | INSULATE BARE EQUIPMENT | $3,996 | $0 | Implemented |
UD0817 # 14 Y:2010 | 14 | 2010 | RELOCATE OVEN / FURNACE TO MORE EFFICIENT LOCATION | $300 | $50 | Not Implemented |
UD0817 # 13 Y:2010 | 13 | 2010 | INSULATE BARE EQUIPMENT | $21,893 | $0 | Implemented |
UD0817 # 12 Y:2010 | 12 | 2010 | COVER OPEN TANKS | $10,386 | $0 | Implemented |
UD0817 # 11 Y:2010 | 11 | 2010 | USE OPTIMUM TEMPERATURE | $8,137 | $0 | Implemented |
UD0817 # 10 Y:2010 | 10 | 2010 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $3,001 | $2,366 | Not Implemented |
UD0817 # 09 Y:2010 | 09 | 2010 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,120 | $0 | Implemented |
UD0817 # 08 Y:2010 | 08 | 2010 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $4,696 | $2,250 | Not Implemented |
UD0817 # 07 Y:2010 | 07 | 2010 | REMOVE OR CLOSE OFF UNNEEDED COMPRESSED AIR LINES | $628 | $0 | Implemented |
UD0817 # 06 Y:2010 | 06 | 2010 | UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT | $1,712 | $7,628 | Not Implemented |
UD0817 # 05 Y:2010 | 05 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $10,546 | $3,000 | Not Implemented |
UD0817 # 03 Y:2010 | 03 | 2010 | USE PLANT OWNED TRANSFORMERS OR LEASE TRANSFORMERS | $9,387 | $0 | Not Implemented |
UD0817 # 02 Y:2010 | 02 | 2010 | OPTIMIZE PLANT POWER FACTOR | $63,586 | $41,250 | Not Implemented |
UD0817 # 01 Y:2010 | 01 | 2010 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $66,672 | $600 | Implemented |
OK0785 # 01 Y:2010 | 01 | 2010 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $7,282 | $55,440 | Implemented |
UD0811 # 05 Y:2010 | 05 | 2010 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $12,579 | $50,000 | Not Implemented |
UD0811 # 04 Y:2010 | 04 | 2010 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $646 | $0 | Not Implemented |
UD0811 # 03 Y:2010 | 03 | 2010 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $897 | $1,000 | Not Implemented |
UD0811 # 02 Y:2010 | 02 | 2010 | CLOSE HOLES AND OPENINGS IN BUILDING SUCH AS BROKEN WINDOWS | $7,064 | $13,132 | Not Implemented |
UD0811 # 01 Y:2010 | 01 | 2010 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $27,175 | $0 | Not Implemented |
OK0785 # 06 Y:2010 | 06 | 2010 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $563 | $0 | Implemented |