Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
791
matching recommendationsNAICS | 33131 | Alumina and Aluminum Production and Processing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UF0448 # 03 Y:2011 | 03 | 2011 | LOWER LIGHT FIXTURES IN HIGH CEILING AREAS | $20,728 | $4,066 | Not Implemented |
UF0448 # 04 Y:2011 | 04 | 2011 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $6,395 | $1,400 | Not Implemented |
UF0448 # 05 Y:2011 | 05 | 2011 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $2,034 | $1,627 | Not Implemented |
UF0448 # 06 Y:2011 | 06 | 2011 | INSTALL OCCUPANCY SENSORS | $3,138 | $1,469 | Not Implemented |
UF0448 # 07 Y:2011 | 07 | 2011 | INSTALL OCCUPANCY SENSORS | $3,518 | $2,040 | Implemented |
UF0448 # 08 Y:2011 | 08 | 2011 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $24,397 | $9,355 | Implemented |
UF0448 # 09 Y:2011 | 09 | 2011 | USE COMPRESSOR AIR FILTERS | $7,367 | $1,634 | Not Implemented |
UF0448 # 10 Y:2011 | 10 | 2011 | INSULATE BARE EQUIPMENT | $5,708 | $4,205 | Not Implemented |
UF0448 # 11 Y:2011 | 11 | 2011 | REPAIR FAULTY INSULATION IN FURNACES, BOILERS, ETC | $291 | $1,730 | Not Implemented |
UF0448 # 12 Y:2011 | 12 | 2011 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $515,044 | $294,885 | Not Implemented |
MZ0058 # 01 Y:2010 | 01 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $37,229 | $41,660 | Implemented |
MZ0058 # 02 Y:2010 | 02 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $9,522 | $22,400 | Implemented |
MZ0058 # 03 Y:2010 | 03 | 2010 | RECOVER WASTE HEAT FROM EQUIPMENT | $422,776 | $140,000 | Implemented |
MZ0058 # 04 Y:2010 | 04 | 2010 | USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE | $775 | $360 | Not Implemented |
MZ0058 # 05 Y:2010 | 05 | 2010 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $7,085 | $1,300 | Implemented |
MZ0058 # 06 Y:2010 | 06 | 2010 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $5,916 | $0 | Implemented |
MZ0058 # 07 Y:2010 | 07 | 2010 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,663 | $0 | Not Implemented |
UM0378 # 01 Y:2010 | 01 | 2010 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $14,490 | $31,638 | Implemented |
UM0378 # 02 Y:2010 | 02 | 2010 | UPGRADE CONTROLS ON COMPRESSORS | $2,693 | $3,996 | Implemented |
UM0378 # 03 Y:2010 | 03 | 2010 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $755 | $1,000 | Implemented |
UM0378 # 04 Y:2010 | 04 | 2010 | CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES | $102 | $10 | Not Implemented |
UM0378 # 05 Y:2010 | 05 | 2010 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $68,485 | $2,000 | Implemented |
UM0378 # 06 Y:2010 | 06 | 2010 | RECOVER WASTE HEAT FROM EQUIPMENT | $3,599 | $1,500 | Implemented |
UM0378 # 07 Y:2010 | 07 | 2010 | RECOVER HEAT FROM EXHAUSTED STEAM, HOT AIR OR HOT WATER | $3,345 | $7,800 | Implemented |
LL0337 # 01 Y:2010 | 01 | 2010 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $88,374 | $59,360 | Implemented |