Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
594
matching recommendationsNAICS | 3314 | Nonferrous Metal (except Aluminum) Production and Processing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UF0359 # 05 Y:2005 | 05 | 2005 | CHANGE OPERATING CONDITIONS | $15,046 | $0 | Implemented |
NC0303 # 01 Y:2004 | 01 | 2004 | ADOPT IN-HOUSE MATERIAL GENERATION | $34,730 | $120,000 | Not Implemented |
NC0303 # 02 Y:2004 | 02 | 2004 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $20,788 | $0 | Not Implemented |
NC0303 # 03 Y:2004 | 03 | 2004 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $18,426 | $18,825 | Not Implemented |
NC0303 # 04 Y:2004 | 04 | 2004 | REPLACE THE CHLORINATION STAGE WITH AN OXYGEN OR OZONE STAGE | $11,844 | $18,280 | Not Implemented |
NC0303 # 05 Y:2004 | 05 | 2004 | REDESIGN PROCESS | $73,700 | $35,000 | Not Implemented |
NC0303 # 06 Y:2004 | 06 | 2004 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,224 | $100 | Implemented |
NC0303 # 07 Y:2004 | 07 | 2004 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,085 | $1,385 | Not Implemented |
UF0351 # 01 Y:2004 | 01 | 2004 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $3,410 | $1,004 | Implemented |
UF0351 # 02 Y:2004 | 02 | 2004 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $7,704 | $5,952 | Implemented |
UF0351 # 03 Y:2004 | 03 | 2004 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $22,503 | $0 | Not Implemented |
UF0351 # 04 Y:2004 | 04 | 2004 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,480 | $3,600 | Not Implemented |
UF0351 # 05 Y:2004 | 05 | 2004 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $14,215 | $35,243 | Implemented |
UF0351 # 06 Y:2004 | 06 | 2004 | DIRECT WARMEST AIR TO COMBUSTION INTAKE | $16,846 | $85,000 | Not Implemented |
UF0351 # 07 Y:2004 | 07 | 2004 | RECOVER METALS FROM SPENT SOLUTIONS AND RECYCLE | $225,920 | $200,000 | Not Implemented |
WV0288 # 01 Y:2004 | 01 | 2004 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $12,469 | $2,195 | Not Implemented |
WV0288 # 02 Y:2004 | 02 | 2004 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $9,141 | $360 | Implemented |
WV0288 # 03 Y:2004 | 03 | 2004 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $9,120 | $700 | Not Implemented |
WV0288 # 04 Y:2004 | 04 | 2004 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $8,061 | $250 | Not Implemented |
WV0288 # 05 Y:2004 | 05 | 2004 | USE WASTE HEAT FROM FLUE GASES TO HEAT SPACE CONDITIONING AIR | $6,212 | $1,200 | Implemented |
WV0288 # 06 Y:2004 | 06 | 2004 | REPLACE OBSOLETE BURNERS WITH MORE EFFICIENT ONES | $5,772 | $27,600 | Implemented |
WV0288 # 07 Y:2004 | 07 | 2004 | DEVELOP A REPAIR/REPLACE POLICY | $4,573 | $1,000 | Implemented |
WV0288 # 08 Y:2004 | 08 | 2004 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,040 | $3,210 | Not Implemented |
WV0288 # 09 Y:2004 | 09 | 2004 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $3,932 | $50 | Implemented |
WV0288 # 10 Y:2004 | 10 | 2004 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $3,739 | $575 | Implemented |