Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
2,045
matching recommendationsNAICS | 3315 | Foundries |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UD0749 # 06 Y:2006 | 06 | 2006 | MINIMIZE NON-ESSENTIAL MATERIAL IN HEAT TREATMENT PROCESS | $127,000 | $20,000 | Not Implemented |
UD0749 # 07 Y:2006 | 07 | 2006 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $111,197 | $15,000 | Not Implemented |
UD0749 # 08 Y:2006 | 08 | 2006 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $98,501 | $34,560 | Implemented |
UD0749 # 09 Y:2006 | 09 | 2006 | UPGRADE CONTROLS ON COMPRESSORS | $25,009 | $45,000 | Implemented |
UD0749 # 10 Y:2006 | 10 | 2006 | INSTALL TIMERS AND/OR THERMOSTATS | $22,598 | $20,000 | Implemented |
UD0749 # 11 Y:2006 | 11 | 2006 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $5,254 | $0 | Implemented |
UD0749 # 12 Y:2006 | 12 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,896 | $13,819 | Not Implemented |
UD0749 # 13 Y:2006 | 13 | 2006 | USE MINIMUM SAFE OVEN VENTILATION | $4,400 | $0 | Implemented |
UM0307 # 01 Y:2006 | 01 | 2006 | REPAIR FURNACES AND OVEN DOORS SO THAT THEY SEAL EFFICIENTLY | $302,929 | $70,000 | Implemented |
UM0307 # 02 Y:2006 | 02 | 2006 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $219,438 | $0 | Not Implemented |
UM0307 # 03 Y:2006 | 03 | 2006 | MINIMIZE OPERATION OF EQUIPMENT MAINTAINED IN STANDBY CONDITION | $63,131 | $0 | Implemented |
UM0307 # 04 Y:2006 | 04 | 2006 | ADJUST BURNERS FOR EFFICIENT OPERATION | $55,043 | $2,400 | Implemented |
UM0307 # 05 Y:2006 | 05 | 2006 | REPAIR FURNACES AND OVEN DOORS SO THAT THEY SEAL EFFICIENTLY | $19,061 | $5,066 | Implemented |
UM0307 # 06 Y:2006 | 06 | 2006 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $14,621 | $1,500 | Implemented |
UM0307 # 07 Y:2006 | 07 | 2006 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $10,914 | $5,000 | Not Implemented |
UM0307 # 08 Y:2006 | 08 | 2006 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $10,428 | $2,000 | Implemented |
UM0307 # 09 Y:2006 | 09 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $6,814 | $10,054 | Implemented |
UM0307 # 10 Y:2006 | 10 | 2006 | INSULATE BARE EQUIPMENT | $3,606 | $1,191 | Implemented |
UM0307 # 11 Y:2006 | 11 | 2006 | RECOVER WASTE HEAT FROM EQUIPMENT | $3,358 | $2,100 | Not Implemented |
UM0307 # 12 Y:2006 | 12 | 2006 | INSULATE BARE EQUIPMENT | $3,085 | $0 | Implemented |
UM0307 # 13 Y:2006 | 13 | 2006 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $754 | $75 | Implemented |
UD0742 # 01 Y:2006 | 01 | 2006 | REPLACE FOSSIL FUEL EQUIPMENT WITH ELECTRICAL EQUIPMENT | $314,266 | $2,000,000 | Not Implemented |
UD0742 # 02 Y:2006 | 02 | 2006 | UPGRADE CONTROLS ON COMPRESSORS | $198,228 | $100,000 | Implemented |
UD0742 # 03 Y:2006 | 03 | 2006 | USE ONLY AMOUNT OF AIR NECESSARY TO PREVENT EXPLOSION HAZARD | $185,439 | $0 | Not Implemented |
UD0742 # 04 Y:2006 | 04 | 2006 | REDESIGN PROCESS | $174,377 | $0 | Implemented |