Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
317
matching recommendationsNAICS | 3315 | Foundries |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
WV0349 # 01 Y:2006 | 01 | 2006 | PREHEAT COMBUSTION AIR WITH WASTE HEAT | $167,255 | $32,010 | Not Implemented |
WV0349 # 02 Y:2006 | 02 | 2006 | USE WASTE HEAT FROM FLUE GASES TO HEAT SPACE CONDITIONING AIR | $48,286 | $39,350 | Implemented |
WV0349 # 03 Y:2006 | 03 | 2006 | RECOVER WASTE HEAT FROM EQUIPMENT | $14,527 | $640 | Implemented |
WV0349 # 04 Y:2006 | 04 | 2006 | REDUCE VENTILATION AIR | $13,672 | $10,295 | Implemented |
WV0349 # 05 Y:2006 | 05 | 2006 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $10,522 | $600 | Not Implemented |
WV0349 # 06 Y:2006 | 06 | 2006 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $7,322 | $3,250 | Not Implemented |
WV0349 # 07 Y:2006 | 07 | 2006 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $5,242 | $400 | Implemented |
WV0349 # 08 Y:2006 | 08 | 2006 | ESTABLISH A PREDICTIVE MAINTENANCE PROGRAM | $4,291 | $1,000 | Implemented |
WV0349 # 09 Y:2006 | 09 | 2006 | INSULATE BARE EQUIPMENT | $3,740 | $1,318 | Implemented |
WV0349 # 10 Y:2006 | 10 | 2006 | OPTIMIZE PLANT POWER FACTOR | $3,456 | $10,700 | Not Implemented |
WV0349 # 12 Y:2006 | 12 | 2006 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $375 | $200 | Implemented |
WV0349 # 11 Y:2006 | 11 | 2006 | DEVELOP A REPAIR/REPLACE POLICY | $1,998 | $512 | Implemented |
UD0749 # 01 Y:2006 | 01 | 2006 | REPLACE HEAT TREATING OVEN WITH MORE EFFICIENT UNIT | $973,467 | $1,500,000 | Not Implemented |
UD0749 # 02 Y:2006 | 02 | 2006 | REDUCE VENTILATION AIR | $359,088 | $0 | Not Implemented |
UD0749 # 03 Y:2006 | 03 | 2006 | REDUCE COMBUSTION AIR FLOW TO OPTIMUM | $211,000 | $7,200 | Implemented |
UD0749 # 04 Y:2006 | 04 | 2006 | HEAT TREAT PARTS ONLY TO REQUIRED SPECIFICATIONS OR STANDARDS | $151,097 | $0 | Not Implemented |
UD0749 # 05 Y:2006 | 05 | 2006 | INSULATE BARE EQUIPMENT | $128,436 | $44,181 | Implemented |
UD0749 # 06 Y:2006 | 06 | 2006 | MINIMIZE NON-ESSENTIAL MATERIAL IN HEAT TREATMENT PROCESS | $127,000 | $20,000 | Not Implemented |
UD0749 # 07 Y:2006 | 07 | 2006 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $111,197 | $15,000 | Not Implemented |
UD0749 # 08 Y:2006 | 08 | 2006 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $98,501 | $34,560 | Implemented |
UD0749 # 09 Y:2006 | 09 | 2006 | UPGRADE CONTROLS ON COMPRESSORS | $25,009 | $45,000 | Implemented |
UD0749 # 10 Y:2006 | 10 | 2006 | INSTALL TIMERS AND/OR THERMOSTATS | $22,598 | $20,000 | Implemented |
UD0749 # 11 Y:2006 | 11 | 2006 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $5,254 | $0 | Implemented |
UD0749 # 12 Y:2006 | 12 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,896 | $13,819 | Not Implemented |
UD0749 # 13 Y:2006 | 13 | 2006 | USE MINIMUM SAFE OVEN VENTILATION | $4,400 | $0 | Implemented |