Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
73
matching recommendationsNAICS | 3315 | Foundries |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
CM1014 # 03 Y:2022 | 03 | 2022 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $4,968 | $600 | n/a |
CM1014 # 02 Y:2022 | 02 | 2022 | USE RADIANT HEATER FOR SPOT HEATING | $5,400 | $3,600 | n/a |
CM1014 # 04 Y:2022 | 04 | 2022 | CLOSE HOLES AND OPENINGS IN BUILDING SUCH AS BROKEN WINDOWS | $400 | $1,500 | n/a |
CM1014 # 01 Y:2022 | 01 | 2022 | USE SOLAR HEAT TO MAKE ELECTRICTY | $75,700 | $662,500 | n/a |
IP0168 # 02 Y:2022 | 02 | 2022 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $61,060 | $8,140 | Implemented |
IP0168 # 01 Y:2022 | 01 | 2022 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $5,243 | $0 | Implemented |
IP0168 # 10 Y:2022 | 10 | 2022 | USE PHOTOCELL CONTROLS | $237 | $727 | Implemented |
IP0168 # 09 Y:2022 | 09 | 2022 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $254 | $600 | Implemented |
IP0168 # 08 Y:2022 | 08 | 2022 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $5,542 | $5,311 | Implemented |
IP0168 # 07 Y:2022 | 07 | 2022 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $939 | $713 | Implemented |
IP0168 # 06 Y:2022 | 06 | 2022 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $8,045 | $4,576 | Implemented |
IP0168 # 05 Y:2022 | 05 | 2022 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $9,513 | $4,848 | Implemented |
IP0168 # 04 Y:2022 | 04 | 2022 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $53,112 | $22,920 | Implemented |
IP0168 # 03 Y:2022 | 03 | 2022 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $86,815 | $12,140 | Implemented |
UC2207 # 01 Y:2022 | 01 | 2022 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $378 | $464 | Not Implemented |
UC2207 # 04 Y:2022 | 04 | 2022 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,359 | $2,800 | Not Implemented |
UC2207 # 07 Y:2022 | 07 | 2022 | USE SOLAR HEAT TO MAKE ELECTRICTY | $70,713 | $379,682 | Not Implemented |
UC2207 # 06 Y:2022 | 06 | 2022 | CONVERT COMBUSTION EQUIPMENT TO BURN NATURAL GAS | $4,478 | $3,300 | Not Implemented |
UC2207 # 02 Y:2022 | 02 | 2022 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $2,727 | $500 | Not Implemented |
UC2207 # 03 Y:2022 | 03 | 2022 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $12,731 | $500 | Not Implemented |
UC2207 # 05 Y:2022 | 05 | 2022 | TURN OFF EQUIPMENT WHEN NOT IN USE | $2,876 | $500 | Not Implemented |
MU0019 # 04 Y:2022 | 04 | 2022 | CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES | $1,514 | $610 | Not Implemented |
MU0019 # 03 Y:2022 | 03 | 2022 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $45,007 | $800 | Implemented |
MU0019 # 02 Y:2022 | 02 | 2022 | USE PHOTOCELL CONTROLS | $386 | $133 | Not Implemented |
MU0019 # 01 Y:2022 | 01 | 2022 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $306 | $40 | Not Implemented |