1,047
matching recommendationsNAICS | 33151 | Ferrous Metal Foundries |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
GT0759 # 03 Y:2003 | 03 | 2003 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $33,765 | $188,200 | Implemented |
GT0759 # 04 Y:2003 | 04 | 2003 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $200,910 | $20,900 | n/a |
GT0759 # 05 Y:2003 | 05 | 2003 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $157,690 | $210,000 | n/a |
GT0759 # 06 Y:2003 | 06 | 2003 | IMPROVE COMBUSTION CONTROL CAPABILITY | $287,380 | $24,500 | n/a |
GT0759 # 07 Y:2003 | 07 | 2003 | USE RADIANT HEATER FOR SPOT HEATING | $5,960 | $2,190 | Implemented |
GT0759 # 08 Y:2003 | 08 | 2003 | RECOVER WASTE HEAT FROM EQUIPMENT | $89,620 | $108,930 | Implemented |
GT0756 # 01 Y:2003 | 01 | 2003 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $510 | $1,100 | n/a |
GT0756 # 02 Y:2003 | 02 | 2003 | COVER OPEN TANKS | $18,300 | $3,000 | n/a |
GT0756 # 03 Y:2003 | 03 | 2003 | ENHANCE SENSITIVITY OF TEMPERATURE CONTROL AND CUTOFF | $22,800 | $5,610 | n/a |
GT0756 # 04 Y:2003 | 04 | 2003 | USE INSULATION IN FURNACES TO FACILITATE HEATING / COOLING | $2,950 | $1,620 | n/a |
GT0756 # 05 Y:2003 | 05 | 2003 | USE CLOSED CYCLE PROCESS TO MINIMIZE WASTE WATER PRODUCTION | $10,000 | $35,955 | n/a |
GT0756 # 06 Y:2003 | 06 | 2003 | METER RECYCLED WATER (TO REDUCE SEWER CHARGES) | $2,680 | $1,850 | n/a |
GT0756 # 07 Y:2003 | 07 | 2003 | RESCHEDULE AND REARRANGE MULTIPLE-SOURCE HEATING SYSTEMS | $56,040 | $1,500 | n/a |
GT0756 # 08 Y:2003 | 08 | 2003 | REPLACE ELECTRIC MOTOR WITH FOSSIL FUEL ENGINE | $89,400 | $200,000 | n/a |
GT0756 # 09 Y:2003 | 09 | 2003 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $784 | $0 | n/a |
GT0756 # 10 Y:2003 | 10 | 2003 | UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT | $5,098 | $10,980 | n/a |
GT0756 # 11 Y:2003 | 11 | 2003 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $3,820 | $0 | n/a |
GT0756 # 12 Y:2003 | 12 | 2003 | INSULATE BARE EQUIPMENT | $1,474 | $1,730 | n/a |
GT0756 # 13 Y:2003 | 13 | 2003 | TURN OFF EQUIPMENT WHEN NOT IN USE | $556 | $0 | n/a |
GT0756 # 14 Y:2003 | 14 | 2003 | COMBINE UTILITY METERS | $2,980 | $0 | n/a |
GT0756 # 15 Y:2003 | 15 | 2003 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $2,065 | $0 | n/a |
TA0051 # 01 Y:2003 | 01 | 2003 | CHANGE PROCEDURES / EQUIPMENT / OPERATING CONDITIONS | $1,410,425 | $467,000 | Not Implemented |
TA0051 # 02 Y:2003 | 02 | 2003 | USE FLUE GASES TO HEAT PROCESS OR SERVICE WATER | $53,166 | $17,450 | Implemented |
TA0051 # 03 Y:2003 | 03 | 2003 | REPLACE OLD MACHINE WITH NEW AUTOMATIC MULTI-STATION TOOL | $48,231 | $30,800 | Not Implemented |
TA0051 # 04 Y:2003 | 04 | 2003 | RECOVER AND REUSE COOLING WATER | $19,775 | $51,000 | Implemented |