Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
90
matching recommendationsNAICS | 331523 | Nonferrous Metal Die-Casting Foundries |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UD0742 # 19 Y:2006 | 19 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $874 | $867 | Implemented |
UD0742 # 18 Y:2006 | 18 | 2006 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $3,020 | $0 | Implemented |
UD0742 # 17 Y:2006 | 17 | 2006 | USE OPTIMUM THICKNESS INSULATION | $4,031 | $9,057 | Not Implemented |
UD0742 # 16 Y:2006 | 16 | 2006 | REDUCE WATER USE WITH COUNTER CURRENT RINSING | $7,083 | $0 | Implemented |
UD0742 # 15 Y:2006 | 15 | 2006 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $9,232 | $5,000 | Not Implemented |
UD0742 # 14 Y:2006 | 14 | 2006 | UPGRADE CONTROLS ON COMPRESSORS | $17,949 | $0 | Implemented |
UD0742 # 13 Y:2006 | 13 | 2006 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $18,813 | $51,160 | Not Implemented |
UD0742 # 12 Y:2006 | 12 | 2006 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $19,230 | $0 | Implemented |
UD0742 # 10 Y:2006 | 10 | 2006 | USE OPTIMUM THICKNESS INSULATION | $42,660 | $15,558 | Not Implemented |
UD0726 # 02 Y:2005 | 02 | 2005 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $157,981 | $295,540 | Not Implemented |
UD0726 # 16 Y:2005 | 16 | 2005 | UPGRADE CONTROLS ON COMPRESSORS | $1,253 | $0 | Implemented |
UD0726 # 01 Y:2005 | 01 | 2005 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $222,216 | $3,730 | Implemented |
UD0726 # 03 Y:2005 | 03 | 2005 | USE OPTIMUM THICKNESS INSULATION | $113,135 | $17,165 | Not Implemented |
UD0726 # 04 Y:2005 | 04 | 2005 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $93,662 | $72,100 | Implemented |
UD0726 # 05 Y:2005 | 05 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $27,707 | $93,840 | Implemented |
UD0726 # 06 Y:2005 | 06 | 2005 | REDUCE VENTILATION AIR | $26,800 | $0 | Implemented |
UD0726 # 07 Y:2005 | 07 | 2005 | INSULATE BARE EQUIPMENT | $19,788 | $4,000 | Implemented |
UD0726 # 08 Y:2005 | 08 | 2005 | USE HEAT IN FLUE GASES TO PREHEAT PRODUCTS OR MATERIALS | $19,593 | $40,000 | Not Implemented |
UD0726 # 10 Y:2005 | 10 | 2005 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $4,819 | $12,560 | Implemented |
UD0726 # 11 Y:2005 | 11 | 2005 | COVER OPEN TANKS | $4,429 | $1,200 | Implemented |
UD0726 # 12 Y:2005 | 12 | 2005 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $4,280 | $736 | Implemented |
UD0726 # 13 Y:2005 | 13 | 2005 | UPGRADE CONTROLS ON COMPRESSORS | $3,679 | $0 | Implemented |
UD0726 # 14 Y:2005 | 14 | 2005 | SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY | $1,948 | $500 | Not Implemented |
UD0726 # 15 Y:2005 | 15 | 2005 | CHECK FOR ACCURACY OF UTILITY / POWER METERS | $1,554 | $0 | Implemented |
UD0726 # 17 Y:2005 | 17 | 2005 | UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT | $412 | $960 | Implemented |