Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
468
matching recommendationsNAICS | 331523 | Nonferrous Metal Die-Casting Foundries |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
OK0873 # 02 Y:2014 | 02 | 2014 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,314 | $2,816 | Not Implemented |
OK0873 # 03 Y:2014 | 03 | 2014 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $7,978 | $9,770 | Not Implemented |
OK0873 # 04 Y:2014 | 04 | 2014 | USE RADIANT HEATER FOR SPOT HEATING | $21,894 | $7,500 | Not Implemented |
OK0873 # 05 Y:2014 | 05 | 2014 | USE CLOSED CYCLE PROCESS TO MINIMIZE WASTE WATER PRODUCTION | $100,171 | $14,950 | Not Implemented |
OK0873 # 06 Y:2014 | 06 | 2014 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $102,361 | $450,000 | Implemented |
OK0873 # 07 Y:2014 | 07 | 2014 | COVER OPEN TANKS | $9,771 | $0 | Implemented |
OK0873 # 08 Y:2014 | 08 | 2014 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $24,004 | $63,370 | Not Implemented |
OK0873 # 09 Y:2014 | 09 | 2014 | OPTIMIZE PLANT POWER FACTOR | $9,509 | $11,638 | Not Implemented |
WM0026 # 01 Y:2013 | 01 | 2013 | INSULATE GLAZING, WALLS, CEILINGS, AND ROOFS | $586 | $424 | Not Implemented |
WM0026 # 02 Y:2013 | 02 | 2013 | INSTALL OCCUPANCY SENSORS | $1,319 | $2,730 | Not Implemented |
WM0026 # 03 Y:2013 | 03 | 2013 | AIR CONDITION ONLY SPACE NECESSARY | $2,884 | $0 | Not Implemented |
WM0026 # 04 Y:2013 | 04 | 2013 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $1,454 | $1,526 | Implemented |
WM0026 # 05 Y:2013 | 05 | 2013 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $239 | $410 | Not Implemented |
WM0026 # 06 Y:2013 | 06 | 2013 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $18,054 | $33,056 | Implemented |
BD0427 # 01 Y:2013 | 01 | 2013 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $2,899 | $10 | Not Implemented |
BD0427 # 02 Y:2013 | 02 | 2013 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $6,216 | $900 | Not Implemented |
BD0427 # 03 Y:2013 | 03 | 2013 | USE SYNTHETIC LUBRICANT | $1,748 | $750 | Implemented |
BD0427 # 04 Y:2013 | 04 | 2013 | DIRECT WARMEST AIR TO COMBUSTION INTAKE | $4,369 | $4,000 | Not Implemented |
BD0427 # 05 Y:2013 | 05 | 2013 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,233 | $2,210 | Implemented |
BD0427 # 06 Y:2013 | 06 | 2013 | USE RADIANT HEATER FOR SPOT HEATING | $5,309 | $5,700 | Not Implemented |
BD0427 # 07 Y:2013 | 07 | 2013 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $787 | $1,160 | Not Implemented |
BD0427 # 08 Y:2013 | 08 | 2013 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $10,296 | $38,000 | Not Implemented |
BD0425 # 01 Y:2013 | 01 | 2013 | USE RADIANT HEATER FOR SPOT HEATING | $22,668 | $34,200 | Not Implemented |
BD0425 # 02 Y:2013 | 02 | 2013 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $28,900 | $16,000 | Not Implemented |
BD0425 # 03 Y:2013 | 03 | 2013 | INSTALL / REPAIR INSULATION ON STEAM LINES | $1,154 | $1,077 | Implemented |