Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
4,503
matching recommendationsNAICS | 332 | Fabricated Metal Product Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
WV0431 # 01 Y:2011 | 01 | 2011 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $135,254 | $682,000 | Implemented |
WV0431 # 04 Y:2011 | 04 | 2011 | ESTABLISH A PREDICTIVE MAINTENANCE PROGRAM | $7,105 | $1,850 | Implemented |
WV0431 # 05 Y:2011 | 05 | 2011 | DEVELOP A REPAIR/REPLACE POLICY | $6,207 | $1,076 | Implemented |
WV0431 # 07 Y:2011 | 07 | 2011 | INSTALL OCCUPANCY SENSORS | $2,808 | $408 | Implemented |
WV0431 # 08 Y:2011 | 08 | 2011 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $1,027 | $1,560 | Implemented |
BD0394 # 03 Y:2011 | 03 | 2011 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $6,544 | $2,400 | Implemented |
BD0394 # 04 Y:2011 | 04 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,571 | $2,360 | Implemented |
BD0394 # 05 Y:2011 | 05 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,201 | $1,652 | Implemented |
BD0394 # 06 Y:2011 | 06 | 2011 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,201 | $400 | Implemented |
BD0394 # 07 Y:2011 | 07 | 2011 | INSTALL OCCUPANCY SENSORS | $855 | $225 | Implemented |
NC0426 # 02 Y:2011 | 02 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $815 | $1,530 | Implemented |
NC0426 # 05 Y:2011 | 05 | 2011 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $302 | $25 | Implemented |
NC0426 # 06 Y:2011 | 06 | 2011 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $98 | $100 | Implemented |
UM0391 # 04 Y:2011 | 04 | 2011 | REPAIR FURNACES AND OVEN DOORS SO THAT THEY SEAL EFFICIENTLY | $4,244 | $1,000 | Implemented |
WV0428 # 03 Y:2011 | 03 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $40,236 | $60,550 | Implemented |
WV0428 # 05 Y:2011 | 05 | 2011 | DEVELOP A REPAIR/REPLACE POLICY | $11,317 | $815 | Implemented |
WV0428 # 06 Y:2011 | 06 | 2011 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $9,763 | $1,000 | Implemented |
WV0428 # 09 Y:2011 | 09 | 2011 | ESTABLISH A PREDICTIVE MAINTENANCE PROGRAM | $7,253 | $2,000 | Implemented |
WV0428 # 10 Y:2011 | 10 | 2011 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $7,120 | $700 | Implemented |
WV0428 # 14 Y:2011 | 14 | 2011 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $4,082 | $600 | Implemented |
WV0428 # 15 Y:2011 | 15 | 2011 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $2,154 | $25 | Implemented |
AM0599 # 01 Y:2011 | 01 | 2011 | OPTIMIZE PLANT POWER FACTOR | $17,840 | $28,410 | Implemented |
AM0599 # 02 Y:2011 | 02 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $15,590 | $24,740 | Implemented |
AM0599 # 03 Y:2011 | 03 | 2011 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $6,240 | $13 | Implemented |
AM0599 # 04 Y:2011 | 04 | 2011 | INSTALL SKYLIGHTS | $5,535 | $0 | Implemented |