Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
948
matching recommendationsNAICS | 332 | Fabricated Metal Product Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UD0823 # 14 Y:2010 | 14 | 2010 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $1,832 | $9,160 | Not Implemented |
UD0823 # 15 Y:2010 | 15 | 2010 | CLEAN OR COLOR ROOF TO REDUCE SOLAR LOAD | $355 | $25 | Implemented |
UM0372 # 01 Y:2010 | 01 | 2010 | INSTALL OCCUPANCY SENSORS | $2,083 | $2,500 | Implemented |
UM0372 # 02 Y:2010 | 02 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,092 | $25,000 | Implemented |
UM0372 # 03 Y:2010 | 03 | 2010 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $265 | $2,000 | Implemented |
UM0372 # 04 Y:2010 | 04 | 2010 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $645 | $200 | Implemented |
UM0372 # 05 Y:2010 | 05 | 2010 | RECOVER WASTE HEAT FROM EQUIPMENT | $88 | $1,000 | Implemented |
UM0372 # 06 Y:2010 | 06 | 2010 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $2,702 | $3,500 | Implemented |
UM0372 # 07 Y:2010 | 07 | 2010 | COVER OPEN TANKS | $17,216 | $7,182 | Implemented |
UM0372 # 08 Y:2010 | 08 | 2010 | COVER OPEN TANKS | $10,159 | $500 | Implemented |
UM0372 # 09 Y:2010 | 09 | 2010 | COVER OPEN TANKS | $9,602 | $2,472 | Implemented |
UD0819 # 01 Y:2010 | 01 | 2010 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $145,245 | $145,245 | Not Implemented |
UD0819 # 02 Y:2010 | 02 | 2010 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $2,721 | $20 | Not Implemented |
UD0819 # 03 Y:2010 | 03 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $41,439 | $30,037 | Not Implemented |
UD0819 # 04 Y:2010 | 04 | 2010 | UPGRADE OBSOLETE EQUIPMENT | $17,115 | $25,500 | Not Implemented |
UD0819 # 05 Y:2010 | 05 | 2010 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $10,928 | $500 | Not Implemented |
UD0819 # 06 Y:2010 | 06 | 2010 | METER RECYCLED WATER (TO REDUCE SEWER CHARGES) | $5,479 | $1,000 | Not Implemented |
UD0819 # 07 Y:2010 | 07 | 2010 | USE OPTIMUM THICKNESS INSULATION | $33,608 | $35,440 | Not Implemented |
UD0819 # 08 Y:2010 | 08 | 2010 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $22,346 | $44,693 | Not Implemented |
UD0819 # 09 Y:2010 | 09 | 2010 | USE HEAT IN FLUE GASES TO PREHEAT PRODUCTS OR MATERIALS | $11,925 | $7,032 | Not Implemented |
UD0819 # 10 Y:2010 | 10 | 2010 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT INCOMING FLUIDS | $6,484 | $6,000 | Not Implemented |
UD0819 # 11 Y:2010 | 11 | 2010 | USE OPTIMUM TEMPERATURE | $3,080 | $6,160 | Not Implemented |
UD0819 # 12 Y:2010 | 12 | 2010 | USE OPTIMUM TEMPERATURE | $492 | $25 | Not Implemented |
UD0819 # 13 Y:2010 | 13 | 2010 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $9,008 | $6,000 | Not Implemented |
UD0815 # 01 Y:2010 | 01 | 2010 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $2,258 | $0 | Implemented |