Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

10,955

matching recommendations
Reset
NAICS 332 Fabricated Metal Product Manufacturing
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
WV0428 # 12 Y:2011 12 2011 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $5,254 $3,010 Not Implemented
WV0428 # 13 Y:2011 13 2011 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $4,404 $0 Not Implemented
WV0428 # 14 Y:2011 14 2011 REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS $4,082 $600 Implemented
WV0428 # 15 Y:2011 15 2011 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $2,154 $25 Implemented
WV0428 # 16 Y:2011 16 2011 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $2,125 $3,000 Not Implemented
WV0428 # 17 Y:2011 17 2011 REMOVE OR CLOSE OFF UNNEEDED COMPRESSED AIR LINES $860 $0 Not Implemented
WV0428 # 18 Y:2011 18 2011 INSTALL OCCUPANCY SENSORS $391 $770 Not Implemented
AM0599 # 01 Y:2011 01 2011 OPTIMIZE PLANT POWER FACTOR $17,840 $28,410 Implemented
AM0599 # 02 Y:2011 02 2011 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $15,590 $24,740 Implemented
AM0599 # 03 Y:2011 03 2011 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $6,240 $13 Implemented
AM0599 # 04 Y:2011 04 2011 INSTALL SKYLIGHTS $5,535 $0 Implemented
AM0599 # 05 Y:2011 05 2011 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $2,810 $500 Implemented
AM0599 # 06 Y:2011 06 2011 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $1,270 $8,410 Not Implemented
AM0599 # 07 Y:2011 07 2011 USE SYNTHETIC LUBRICANT $790 $0 Not Implemented
AM0599 # 08 Y:2011 08 2011 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED $530 $325 Not Implemented
AM0599 # 09 Y:2011 09 2011 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED $490 $200 Not Implemented
AM0599 # 10 Y:2011 10 2011 OPTIMIZE PLANT POWER FACTOR $415 $1,270 Implemented
SU0309 # 01 Y:2011 01 2011 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $201 $0 Implemented
SU0309 # 02 Y:2011 02 2011 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $255 $147 Implemented
SU0309 # 03 Y:2011 03 2011 INSTALL OCCUPANCY SENSORS $272 $570 Not Implemented
SU0309 # 04 Y:2011 04 2011 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $220 $549 Not Implemented
SU0309 # 05 Y:2011 05 2011 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $68 $228 Implemented
SU0309 # 06 Y:2011 06 2011 CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES $68 $287 Not Implemented
SU0309 # 07 Y:2011 07 2011 UPGRADE OBSOLETE EQUIPMENT $116 $1,258 Implemented
SU0309 # 08 Y:2011 08 2011 UPGRADE OBSOLETE EQUIPMENT $1,442 $16,500 Implemented