Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
10,517
matching recommendationsNAICS | 332 | Fabricated Metal Product Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UM0295 # 10 Y:2006 | 10 | 2006 | USE PHOTOCELL CONTROLS | $878 | $736 | Not Implemented |
NC0331 # 01 Y:2006 | 01 | 2006 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $1,898 | $0 | Not Implemented |
NC0331 # 02 Y:2006 | 02 | 2006 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $7,341 | $500 | Not Implemented |
NC0331 # 03 Y:2006 | 03 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,010 | $50 | Not Implemented |
NC0331 # 04 Y:2006 | 04 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $919 | $803 | Not Implemented |
NC0331 # 05 Y:2006 | 05 | 2006 | BURN A LESS EXPENSIVE GRADE OF FUEL | $11,070 | $25,000 | Not Implemented |
NC0331 # 06 Y:2006 | 06 | 2006 | RECOVER WASTE HEAT FROM EQUIPMENT | $1,252 | $3,726 | Implemented |
NC0331 # 07 Y:2006 | 07 | 2006 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $211 | $100 | Implemented |
NC0331 # 08 Y:2006 | 08 | 2006 | ELIMINATE OLD STOCK AND MODIFY INVENTORY CONTROL | $30,479 | $21,000 | Not Implemented |
UF0374 # 01 Y:2006 | 01 | 2006 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $22,510 | $54,165 | Not Implemented |
UF0374 # 02 Y:2006 | 02 | 2006 | INSULATE BARE EQUIPMENT | $43,329 | $868 | Implemented |
UF0374 # 03 Y:2006 | 03 | 2006 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $9,278 | $12,817 | Implemented |
UF0374 # 04 Y:2006 | 04 | 2006 | IMPROVE SPACE COMFORT CONDITIONING | $6,479 | $13,400 | Not Implemented |
UF0374 # 05 Y:2006 | 05 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $7,506 | $4,360 | Implemented |
UF0374 # 06 Y:2006 | 06 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,005 | $1,355 | Implemented |
UF0374 # 07 Y:2006 | 07 | 2006 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,895 | $1,653 | Implemented |
UF0374 # 08 Y:2006 | 08 | 2006 | INSTALL SKYLIGHTS | $1,181 | $9,627 | Not Implemented |
UF0374 # 09 Y:2006 | 09 | 2006 | RECOVER WASTE HEAT FROM EQUIPMENT | $2,339 | $24,500 | Not Implemented |
UF0374 # 10 Y:2006 | 10 | 2006 | LOWER LIGHT FIXTURES IN HIGH CEILING AREAS | $3,016 | $0 | Implemented |
BD0297 # 01 Y:2006 | 01 | 2006 | USE RADIANT HEATER FOR SPOT HEATING | $18,063 | $50,400 | Not Implemented |
BD0297 # 02 Y:2006 | 02 | 2006 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $11,422 | $1,200 | Implemented |
BD0297 # 03 Y:2006 | 03 | 2006 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $7,740 | $2,500 | Implemented |
BD0297 # 04 Y:2006 | 04 | 2006 | RECOVER WASTE HEAT FROM EQUIPMENT | $2,600 | $600 | Implemented |
BD0297 # 05 Y:2006 | 05 | 2006 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $1,324 | $6,150 | Implemented |
BD0297 # 06 Y:2006 | 06 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $823 | $2,975 | Implemented |